Literature DB >> 9406525

Molecular imaging of biological samples: localization of peptides and proteins using MALDI-TOF MS.

R M Caprioli1, T B Farmer, J Gile.   

Abstract

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used to generate ion images of samples in one or more mass-to-charge (m/z) values, providing the capability of mapping specific molecules to two-dimensional coordinates of the original sample. The high sensitivity of the technique (low-femtomole to attomole levels for proteins and peptides) allows the study of organized biochemical processes occurring in, for example, mammalian tissue sections. The mass spectrometer is used to determine the molecular weights of the molecular in the surface layers of the tissue. Molecules desorbed from the sample typically are singly protonated, giving an ion at (M + H)+, where M is the molecular mass. The procedure involves coating the tissue section, or a blotted imprint of the section, with a thin layer of energy-absorbing matrix and then analyzing the sample to produce an ordered array of mass spectra, each containing nominal m/z values typically covering a range of over 50,000 Da. Images can be displayed in individual m/z values as a selected ion image, which would localize individual compounds in the tissue, or as summed ion images. MALDI ion images of tissue sections can be obtained directly from tissue slices following preparative steps, and this is demonstrated for the mapping of insulin contained in an islet in a section of rat pancreas, hormone peptides in a small area of a section of rat pituitary, and a small protein bound to the membrane of human mucosa cells. Alternatively, imprints of the tissue can be analyzed by blotting the tissue sections on specially prepared targets containing an adsorbent material, e.g., C-18 coated resin beads. Peptides and small proteins bind to the C-18 and create a positive imprint of the tissue which can then be imaged by the mass spectrometer. This is demonstrated for the MALDI ion image analysis of regions of rat splenic pancreas and for an area of rat pituitary traversing the anterior, intermediate, and posterior regions where localized peptides were mapped. In a single spectrum from the anterior/intermediate lobe of a rat pituitary print, over 50 ions corresponding to the peptides present in this tissue were observed as well as precursors, isoforms, and metabolic fragments.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9406525     DOI: 10.1021/ac970888i

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  499 in total

1.  High spatial resolution imaging mass spectrometry and classical histology on a single tissue section.

Authors:  Fabian Deutskens; Junhai Yang; Richard M Caprioli
Journal:  J Mass Spectrom       Date:  2011-06       Impact factor: 1.982

2.  MALDI mass spectrometric imaging of cardiac tissue following myocardial infarction in a rat coronary artery ligation model.

Authors:  Robert F Menger; Whitney L Stutts; Dhanalakshmi S Anbukumar; John A Bowden; David A Ford; Richard A Yost
Journal:  Anal Chem       Date:  2011-12-22       Impact factor: 6.986

3.  Scanning microprobe matrix-assisted laser desorption ionization (SMALDI) mass spectrometry: instrumentation for sub-micrometer resolved LDI and MALDI surface analysis.

Authors:  Bernhard Spengler; Martin Hubert
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

4.  Spatial profiling invertebrate ganglia using MALDI MS.

Authors:  Rebecca Kruse; Jonathan V Sweedler
Journal:  J Am Soc Mass Spectrom       Date:  2003-07       Impact factor: 3.109

5.  Practical quantitative biomedical applications of MALDI-TOF mass spectrometry.

Authors:  Martin Bucknall; Kim Y C Fung; Mark W Duncan
Journal:  J Am Soc Mass Spectrom       Date:  2002-09       Impact factor: 3.109

6.  A secondary ion microprobe ion trap mass spectrometer.

Authors:  Peter J Todd; T Gregory Schaaff
Journal:  J Am Soc Mass Spectrom       Date:  2002-09       Impact factor: 3.109

7.  Automated MALDI matrix coating system for multiple tissue samples for imaging mass spectrometry.

Authors:  William P Mounfield; Timothy J Garrett
Journal:  J Am Soc Mass Spectrom       Date:  2012-01-11       Impact factor: 3.109

8.  Discovering New Lipidomic Features Using Cell Type Specific Fluorophore Expression to Provide Spatial and Biological Specificity in a Multimodal Workflow with MALDI Imaging Mass Spectrometry.

Authors:  Marissa A Jones; Sung Hoon Cho; Nathan Heath Patterson; Raf Van de Plas; Jeffrey M Spraggins; Mark R Boothby; Richard M Caprioli
Journal:  Anal Chem       Date:  2020-05-06       Impact factor: 6.986

9.  A Simple Sonication Improves Protein Signal in Matrix-Assisted Laser Desorption Ionization Imaging.

Authors:  Li-En Lin; Pin-Rui Su; Hsin-Yi Wu; Cheng-Chih Hsu
Journal:  J Am Soc Mass Spectrom       Date:  2018-02-01       Impact factor: 3.109

10.  Unraveling the RNA modification code with mass spectrometry.

Authors:  Richard Lauman; Benjamin A Garcia
Journal:  Mol Omics       Date:  2020-04-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.