Literature DB >> 21416503

Constrained maximum likelihood estimation of the diffusion kurtosis tensor using a Rician noise model.

Jelle Veraart1, Wim Van Hecke, Jan Sijbers.   

Abstract

A computational framework to obtain an accurate quantification of the Gaussian and non-Gaussian component of water molecules' diffusion through brain tissues with diffusion kurtosis imaging, is presented. The diffusion kurtosis imaging model quantifies the kurtosis, the degree of non-Gaussianity, on a direction dependent basis, constituting a higher order diffusion kurtosis tensor, which is estimated in addition to the well-known diffusion tensor. To reconcile with the physical phenomenon of molecular diffusion, both tensor estimates should lie within a physically acceptable range. Otherwise, clinically and artificially significant changes in diffusion (kurtosis) parameters might be confounded. To guarantee physical relevance, we here suggest to estimate both diffusional tensors by maximizing the joint likelihood function of all Rician distributed diffusion weighted images given the diffusion kurtosis imaging model while imposing a set of nonlinear constraints. As shown in this study, correctly accounting for the Rician noise structure is necessary to avoid significant overestimation of the kurtosis values. The performance of the constrained estimator was evaluated and compared to more commonly used strategies during simulations. Human brain data were used to emphasize the need for constrained estimators as not imposing the constraints give rise to constraint violations in about 70% of the brain voxels.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21416503     DOI: 10.1002/mrm.22835

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

Review 1.  Physics, Techniques and Review of Neuroradiological Applications of Diffusion Kurtosis Imaging (DKI).

Authors:  M Marrale; G Collura; M Brai; N Toschi; F Midiri; G La Tona; A Lo Casto; C Gagliardo
Journal:  Clin Neuroradiol       Date:  2015-11-20       Impact factor: 3.649

2.  Diffusion MRI noise mapping using random matrix theory.

Authors:  Jelle Veraart; Els Fieremans; Dmitry S Novikov
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

3.  Does the use of hormonal contraceptives cause microstructural changes in cerebral white matter? Preliminary results of a DTI and tractography study.

Authors:  Timo De Bondt; Wim Van Hecke; Jelle Veraart; Alexander Leemans; Jan Sijbers; Stefan Sunaert; Yves Jacquemyn; Paul M Parizel
Journal:  Eur Radiol       Date:  2012-07-20       Impact factor: 5.315

4.  Biophysical modeling of high field diffusion MRI demonstrates micro-structural aberration in chronic mild stress rat brain.

Authors:  Ahmad Raza Khan; Andrey Chuhutin; Ove Wiborg; Christopher D Kroenke; Jens R Nyengaard; Brian Hansen; Sune Nørhøj Jespersen
Journal:  Neuroimage       Date:  2016-07-05       Impact factor: 6.556

5.  Precision and accuracy of diffusion kurtosis estimation and the influence of b-value selection.

Authors:  Andrey Chuhutin; Brian Hansen; Sune Nørhøj Jespersen
Journal:  NMR Biomed       Date:  2017-08-25       Impact factor: 4.044

6.  Evaluation of the accuracy and precision of the diffusion parameter EStImation with Gibbs and NoisE removal pipeline.

Authors:  Benjamin Ades-Aron; Jelle Veraart; Peter Kochunov; Stephen McGuire; Paul Sherman; Elias Kellner; Dmitry S Novikov; Els Fieremans
Journal:  Neuroimage       Date:  2018-08-02       Impact factor: 6.556

7.  Denoising of diffusion MRI using random matrix theory.

Authors:  Jelle Veraart; Dmitry S Novikov; Daan Christiaens; Benjamin Ades-Aron; Jan Sijbers; Els Fieremans
Journal:  Neuroimage       Date:  2016-08-11       Impact factor: 6.556

Review 8.  The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter.

Authors:  Markus Nilsson; Danielle van Westen; Freddy Ståhlberg; Pia C Sundgren; Jimmy Lätt
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310

9.  Gibbs ringing in diffusion MRI.

Authors:  Jelle Veraart; Els Fieremans; Ileana O Jelescu; Florian Knoll; Dmitry S Novikov
Journal:  Magn Reson Med       Date:  2015-08-10       Impact factor: 4.668

10.  A simple noise correction scheme for diffusional kurtosis imaging.

Authors:  G Russell Glenn; Ali Tabesh; Jens H Jensen
Journal:  Magn Reson Imaging       Date:  2014-08-28       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.