Literature DB >> 21414384

Influence of matrix systems on proximal contact tightness of 2- and 3-surface posterior composite restorations in vivo.

Eva Wirsching1, Bas A C Loomans, Bernd Klaiber, Christof E Dörfer.   

Abstract

OBJECTIVES: To investigate the influence of cavity preparation (MO/DO/MOD) and type of matrix system on proximal contact tightness of direct posterior composite restorations.
MATERIALS AND METHODS: 85 patients in need of a two- or three surface Class II direct composite restoration were randomly divided into two treatment groups. Group 1 was treated with a sectional matrix system combined with a separation ring (Palodent); Group 2 was treated with a circumferential matrix system in combination with a retainer (Tofflemire). Proximal contact tightness was recorded before treatment and directly after finishing the restoration.
RESULTS: For the two-surface cavities use of the separation ring resulted in a statistically significantly tighter proximal contacts at both the mesial and distal site (MO: 2.51±0.81 N; DO: 2.82±1.14 N) compared to the use of the circumferential (MO: -1.08±1.04 N; DO: -0.22±0.87 N) (p=0.01). Regarding the three-surface (MOD) cavities no statistically significant differences were found between the mesial and distal site, nor was there an effect of the used matrix system. No statistically significant influence of cavity design (mesially/distally) was recorded for all cavities (MO, DO and MOD).
CONCLUSIONS: Use of the sectional matrix system in two-surface Class II cavities resulted in statistically significantly tighter proximal contacts than the use of the circumferential matrix system. For the three-surface no statistically significant differences in contact tightness were found between the different matrix systems. Location of the cavity (mesially or distally) did not show to have any statistically significant effect on the obtained proximal contact tightness.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21414384     DOI: 10.1016/j.jdent.2011.03.001

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  6 in total

Review 1.  Sectional matrix: Step-by-step directions for their clinical use.

Authors:  V Alonso de la Peña; R Pernas García; R Pérez García
Journal:  Br Dent J       Date:  2016-01-15       Impact factor: 1.626

Review 2.  Compliance of randomized controlled trials in posterior restorations with the CONSORT statement: a systematic review of methodology.

Authors:  Márcia Rezende; Ana Cristina Rodrigues Martins; Jadson Araújo da Silva; Alessandra Reis; Juliana Larocca de Geus
Journal:  Clin Oral Investig       Date:  2021-09-30       Impact factor: 3.606

3.  Evaluation of Matrix Band Systems for Posterior Proximal Restorations among Egyptian Dentists: A Cross-Sectional Survey.

Authors:  Omar Osama Shaalan
Journal:  Acta Stomatol Croat       Date:  2020-12

4.  Operators' Ease and Satisfaction in Restoring Class II Cavities With Sectional Matrix Versus Circumferential Matrix System at Qassim University Dental Clinics.

Authors:  Mohammed Almushayti; Bilal Arjumand
Journal:  Cureus       Date:  2022-01-05

5.  Sectional matrix solutions: the distorted truth.

Authors:  Oliver Bailey
Journal:  Br Dent J       Date:  2021-11-12       Impact factor: 2.727

6.  Toward a Clinically Reliable Class II Resin Composite Restoration: A Cross-Sectional Study into the Current Clinical Practice among Dentists in Saudi Arabia.

Authors:  Rasha AlSheikh; Khalid S Almulhim; Moamen Abdulkader; Rasha Haridy; Amr S Bugshan; Rand Aldamanhouri; Moataz Elgezawi
Journal:  Int J Dent       Date:  2022-08-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.