| Literature DB >> 21399434 |
Albérico B de Carvalho1, Michael G Stabin, Jeffry A Siegel, John Hunt.
Abstract
This work compared the predicted dose to an individual due to exposure from a radioactive patient using three models (point, line, and volume), for three therapeutic regimens (hyperthyroidism, thyroid cancer, and non-Hodgkin's lymphoma). For the volume source calculations, Monte Carlo simulations employing the Visual Monte Carlo (VMC) code and the voxel phantom FAX were used. For hyperthyroid patients, the point, line, and volume source models predicted doses to exposed individuals of 54, 24, and 14 mSv, respectively, at a distance of 0.3 m, and 4.8, 4.0 and 3.3 mSv at a distance of 1 m. For thyroid cancer patients, the dose values were 85, 38, and 18 mSv at 0.3 m, and 7.6, 6.4, and 4.4 mSv at 1 m, respectively. For non-Hodgkin's lymphoma (NHL) subjects, the doses were 230, 103, and 36 mSv at 0.3 m, and 21, 17, and 10 mSv at 1 m. These results show that patient release based on point source calculations involves unnecessary conservatism.Entities:
Mesh:
Year: 2011 PMID: 21399434 DOI: 10.1097/HP.0b013e3181eacf38
Source DB: PubMed Journal: Health Phys ISSN: 0017-9078 Impact factor: 1.316