A simple, selective, rapid, precise and economical reverse phase high pressure liquid chromatographic method has been developed for the simultaneous estimation of nebivolol and hydrochlorthiazide from pharmaceutical formulation. Phenomenex Gemini C(18) (25 cm×4.6 mm i.d., 5 μ) column with a mobile phase consisting of acetonitrile: 50mM ammonium acetate (adjusted to pH 3.5 using orthophosphoric acid) (70:30 v/v) at a flow rate of 1.0 ml/min was used. Detection was carried out at 254 nm. Probenecid was used as an internal standard. The retention times of probenecid, nebivolol and hydrochlorthiazide were 13.05, 3.32 and 4.25 min, respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for the estimation of these drugs in combined dosage forms.Entities:
Keywords: RP-HPLC method; hydrochlorothiazide; nebivolol; simultaneous estimation
Year: 2008 PMID: 21394278 PMCID: PMC3038306 DOI: 10.4103/0250-474X.45420
Source DB: PubMed Journal: Indian J Pharm Sci ISSN: 0250-474X Impact factor: 0.975
Fig 1Typical chromatogram of sample solution
Peak at 3.32 min is for nebivolol HCl, peak at 4.25 min is for hydrochlorothizide and peak at 13.05 min is for the internal standard, probenecid
SYSTEM SUITABILITY STUDIES
| Parameters | Nebivolol | Hydrochlorothiazide |
|---|---|---|
| Theoretical plate/meter | 4525 | 5249 |
| Resolution factor | 1.75 | 1.75 |
| Asymmetric factor | 0.92 | 1.04 |
| LOD (ng/ml) | 10 | 5.0 |
| LOQ (ng/ml) | 30 | 15 |