Literature DB >> 21392060

Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review.

L B E A Hoeks1, W L Greven, H W de Valk.   

Abstract

AIMS: This study reviews the effect of real-time continuous glucose monitoring systems in diabetes management.
METHODS: A systematic search was performed in PubMed/MEDLINE and EMBASE for randomized controlled trials comparing real-time continuous glucose monitoring systems with self-monitoring blood glucose or non-real-time continuous glucose monitoring systems.
RESULTS: Nine randomized controlled trials were identified. Two studies used a device which is not on the market any more. In this review we focus on the other seven studies. Performing a meta-analysis was not possible because of extensive clinical heterogeneity. Six of seven studies showed some positive effect of real-time continuous glucose monitoring systems on HbA(1c) (HbA(1c) decrease 0.3-0.7% or 3-8 mmol/mol). In some studies, this effect only was shown in subgroups (compliant adult patients). However, the size of effect may be underestimated by better-than-average results in the control group, as self-monitoring blood glucose measurements are carried out more frequently than in usual clinical practice. Despite the goal of lowering HbA(1c) , no more severe hypoglycaemic episodes were seen, except in one study. In contrast, no positive effect was shown with the real-time continuous glucose monitoring system on hypoglycaemia, but randomized controlled trials were not designed or powered to investigate this issue. Time in different glucose strata was assessed only in some trials: two of them showed a significant but small increase in time in euglycaemia.
CONCLUSIONS: Current evidence shows that the real-time continuous glucose monitoring system has a beneficial effect on glycaemic control in adult diabetes patients, without an increase in the incidence of hypoglycaemia. Studies in well-selected patient groups (pregnancy, history of severe hypoglycaemias, Type 2 diabetes) are lacking.
© 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21392060     DOI: 10.1111/j.1464-5491.2010.03177.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  20 in total

1.  Are Systematic Reviews and Meta-Analyses Appropriate Tools for Assessing Evolving Medical Device Technologies?

Authors:  David Price; Claudia Graham; Christopher G Parkin; Thomas A Peyser
Journal:  J Diabetes Sci Technol       Date:  2015-09-29

2.  Continuous glucose monitoring and trend accuracy: news about a trend compass.

Authors:  Matthew Signal; Rebecca Gottlieb; Aaron Le Compte; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2014-05-16

3.  Blood Glucose Levels of Subelite Athletes During 6 Days of Free Living.

Authors:  Felicity Thomas; Chris G Pretty; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

4.  Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors.

Authors:  Rachel M Unruh; Jason R Roberts; Scott P Nichols; Soya Gamsey; Natalie A Wisniewski; Michael J McShane
Journal:  J Diabetes Sci Technol       Date:  2015-06-17

5.  In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors.

Authors:  Ryan Boehm; John Donovan; Disha Sheth; Andrew Durfor; Jason Roberts; Irada Isayeva
Journal:  J Diabetes Sci Technol       Date:  2018-08-03

6.  Comparative Accuracy of 17 Point-of-Care Glucose Meters.

Authors:  Laya Ekhlaspour; Debbie Mondesir; Norman Lautsch; Courtney Balliro; Mallory Hillard; Kendra Magyar; Laura Goergen Radocchia; Aryan Esmaeili; Manasi Sinha; Steven J Russell
Journal:  J Diabetes Sci Technol       Date:  2016-10-03

Review 7.  Continuous glucose monitoring systems for type 1 diabetes mellitus.

Authors:  Miranda Langendam; Yoeri M Luijf; Lotty Hooft; J Hans Devries; Aart H Mudde; Rob J P M Scholten
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

8.  Assessing performance of closed-loop insulin delivery systems by continuous glucose monitoring: drawbacks and way forward.

Authors:  Roman Hovorka; Marianna Nodale; Ahmad Haidar; Malgorzata E Wilinska
Journal:  Diabetes Technol Ther       Date:  2012-10-09       Impact factor: 6.118

9.  Closed-loop basal insulin delivery over 36 hours in adolescents with type 1 diabetes: randomized clinical trial.

Authors:  Daniela Elleri; Janet M Allen; Kavita Kumareswaran; Lalantha Leelarathna; Marianna Nodale; Karen Caldwell; Peiyao Cheng; Craig Kollman; Ahmad Haidar; Helen R Murphy; Malgorzata E Wilinska; Carlo L Acerini; David B Dunger; Roman Hovorka
Journal:  Diabetes Care       Date:  2012-11-27       Impact factor: 19.112

10.  The effect of real-time continuous glucose monitoring in pregnant women with diabetes: a randomized controlled trial.

Authors:  Anna L Secher; Lene Ringholm; Henrik U Andersen; Peter Damm; Elisabeth R Mathiesen
Journal:  Diabetes Care       Date:  2013-01-24       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.