Geometric performance and efficiency of an optical tracking system for daily pre-treatment positioning in pelvic radiotherapy patients.

Winnie Li1, Fanny Sie, Gregory Bootsma, Douglas Moseley, Charles N Catton, David A Jaffray.   

Abstract

The purpose of this study was to characterize the accuracy of a novel in-house optical tracking system (OTS), and to determine its efficiency for daily pre-treatment positioning of pelvic radiotherapy patients compared to conventional optical distance indicator (ODI) methodology. The OTS is comprised of a passive infrared stereoscopic camera, and custom control software for use in assisting radiotherapy patient setup. Initially, the system was calibrated and tested for stability inside a radiation therapy treatment room. Subsequently, under an ethics approved protocol, the clinical efficiency of the OTS was compared to conventional ODI setup methodology through 17 pelvic radiotherapy patients. Differences between orthogonal source-to-skin distance (SSD) readings and overall set-up time resultant from both systems were compared. The precision of the OTS was 0.01 ± 0.01 mm, 0.02 ± 0.02 mm, and -0.01 ± 0.06 mm in the left/right (L/R), anterior/posterior (A/P), and cranial/caudal (C/C) directions, respectively. Discrepancies measured between the linac radiographic center in the treatment room and the calibrated origin of the camera (OTS) by two independent observers was submillimeter. Analysis of 146 fractions from 17 patients showed a high correlation between the SSD readings of the OTS and ODI setup methodologies (r = 0.99). The average time for pre-treatment positioning using the OTS couch shift calculation was 2.60 ± 0.69 minutes, and for conventional ODI setup, 3.62 ± 0.82 minutes; the difference of 1.02 minutes was statistically significant (p < 0.001). In conclusion, the OTS is a precise and robust tool for use as an independent check of treatment room patient positioning. The system is indicated as geometrically equivalent to current methods of daily pre-treatment patient positioning with potential for gains in efficiency by decreasing setup times in the treatment room.

Entities:  

Mesh:

Year:  2011        PMID: 21381794     DOI: 10.7785/tcrt.2012.500191

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  2 in total

1.  Validity of the use of nose tip motion as a surrogate for intracranial motion in mask-fixated frameless Gamma Knife® Icon™ therapy.

Authors:  Gavin Wright; Natalie Harrold; Paul Hatfield; Peter Bownes
Journal:  J Radiosurg SBRT       Date:  2017

2.  Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife.

Authors:  Winnie Li; Gregory Bootsma; Oscar Von Schultz; Per Carlsson; Normand Laperriere; Barbara-Ann Millar; David Jaffray; Caroline Chung
Journal:  Cureus       Date:  2016-03-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.