Literature DB >> 21376953

Electrochemically oriented immobilization of antibody on poly-(2-cyano-ethylpyrrole)-coated gold electrode using a cyclic voltammetry.

Hyun-Ju Um1, Mina Kim, Sang-Hee Lee, Jiho Min, Hongik Kim, Young-Woo Choi, Yang-Hoon Kim.   

Abstract

Using quartz crystal microbalance (QCM) as an immunosensor, this work investigates the contribution of a cyclic voltammetry (CV) on the proper immobilization of antibodies with the aim of enhancing its target recognition and binding ability. Primarily, CV in the range of -0.1 to 0.9 V was applied to form a layer of poly-(2-cyano-ethylpyrrole) (PCEPy) on gold quartz crystal electrode. Then the efficiencies of antibodies (anti-IgG, AIgG) immobilized electrochemically with CV applied in 0-0.65 V were compared to those immobilized via physical adsorption, by observing relative affinity towards AIgG-Fab and AIgG-Fc fragments. The results showed antibody-AIgG-Fab interaction could be enhanced about 4 times when CV is applied (11.2 ± 1.3 vs 41.6 ± 3.4 relative fluorescence unit). On the contrary, physisorbed antibodies showed a higher degree of affinity towards AIgG-Fc indicating inappropriate orientations of physisorbed antibodies. AIgG immobilized PCEPy-gold QC electrode was characterized further for its sensitivity towards a new target bovine albumin with both a QCM and fluorescence measurement. Such electrode exhibited a good sensitivity as well as a large linear dynamic range, from 0.4 μg/ml to 1.0 μg/ml and from 0.5 μg/ml to 10.0 μg/ml, at QCM and fluorescence measurement, respectively.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21376953     DOI: 10.1016/j.talanta.2011.01.013

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

Review 1.  Site-selective orientated immobilization of antibodies and conjugates for immunodiagnostics development.

Authors:  Min Shen; Chandra K Dixit; James Rusling
Journal:  Methods       Date:  2016-11-19       Impact factor: 3.608

2.  A novel assay for detecting canine parvovirus using a quartz crystal microbalance biosensor.

Authors:  Yong Kwan Kim; Seong-In Lim; Sarah Choi; In-Soo Cho; Eun-Hye Park; Dong-Jun An
Journal:  J Virol Methods       Date:  2015-03-23       Impact factor: 2.014

Review 3.  Antibodies and antibody-derived analytical biosensors.

Authors:  Shikha Sharma; Hannah Byrne; Richard J O'Kennedy
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

Review 4.  Study on the interaction between active components from traditional Chinese medicine and plasma proteins.

Authors:  Qishu Jiao; Rufeng Wang; Yanyan Jiang; Bin Liu
Journal:  Chem Cent J       Date:  2018-05-04       Impact factor: 4.215

5.  Screen Printed Based Impedimetric Immunosensor for Rapid Detection of Escherichia coli in Drinking Water.

Authors:  Martina Cimafonte; Andrea Fulgione; Rosa Gaglione; Marina Papaianni; Rosanna Capparelli; Angela Arciello; Sergio Bolletti Censi; Giorgia Borriello; Raffaele Velotta; Bartolomeo Della Ventura
Journal:  Sensors (Basel)       Date:  2020-01-03       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.