Literature DB >> 21373914

Plating of proximal fracture of the humerus: a study of 30 cases.

C Iacobellis1, K Fountzoulas, R Aldegheri.   

Abstract

In recent years, plate osteosynthesis with angular stable implants is frequently used for severely displaced three- and four-part proximal humeral fractures. The aim of this study is to evaluate early results of these fractures treated with insertion of LCP or Philos plates. We present results in 30 cases of proximal humeral fractures, 17 with 3 parts according to Neer and 13 with 4 parts, treated with Locking Compression Plates (LCP, 14 cases) and Philos plates (16) by the deltopectoral approach. Patients were checked with standard X-rays and clinical evaluation, according to the Constant-Murley shoulder score, Individual Constant score and Relative Constant score. Mean follow-up time was 21 months (range 6-42 months). The mean Constant-Murley shoulder scores were Pain 10.6 (3-15), Activities of Daily Living 15.3 (2-20), Range of Motion 26.8 (12-40) and Power 10.3 (3-25) and Total 63 (25-97). The Individual Constant score was 68.6% (27-98%) and the Relative Constant score 85.4% (36-130%). Fractures in 3 parts (of the surgical or anatomic humeral neck and major tubercle) had a mean Constant score of 69.1 (17 cases), but this fell to 55 (13 cases) in those in 4 parts (neck, major and lesser tubercles). Late necrosis of the humeral head occurred in two cases, both with 4-part breaks. We thus believe that 3-part fractures, in which both reduction and stable osteosynthesis are easier, show favourable prognosis and should be clearly distinguished from 4-part ones during assessments. The deltopectoral approach offers good exposure and is especially recommended in 4-part fractures, also because it provides a good view of the lesser tubercle. The osteosynthesis must be stable if early mobilisation of the shoulder and proper recovery of range of motion are to be achieved. As well as reduction and stabilisation of the tubercles, it is also important to restore the neck/shaft angle and stabilise it with oblique screws fitting the plate to avoid varus malposition.

Entities:  

Mesh:

Year:  2011        PMID: 21373914     DOI: 10.1007/s12306-011-0103-1

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  18 in total

1.  Osteosynthesis of Proximal Humeral Fractures with the Fixed Angle PHILOS-plate.

Authors:  Daniela Klitscher; Jochen Blum; Dominik Andreas; Martin Hessmann; Raphael Kuechle; Jean-Baptist du Prel; Pol Maria Rommens
Journal:  Eur J Trauma Emerg Surg       Date:  2007-10-19       Impact factor: 3.693

2.  Locking plate fixation for proximal humeral fractures: initial results with a new implant.

Authors:  Peter S Rose; Christopher R Adams; Michael E Torchia; David J Jacofsky; George G Haidukewych; Scott P Steinmann
Journal:  J Shoulder Elbow Surg       Date:  2006-11-09       Impact factor: 3.019

3.  [The results of internal fixation of proximal humeral fractures with the PHILOS locking plate].

Authors:  Mehmet Fatih Korkmaz; Neslihan Aksu; Abdullah Göğüş; Mürsel Debre; Ayhan Nedim Kara; Zekeriya Uğur Işiklar
Journal:  Acta Orthop Traumatol Turc       Date:  2008 Mar-Apr       Impact factor: 1.511

4.  A clinical method of functional assessment of the shoulder.

Authors:  C R Constant; A H Murley
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

5.  Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures.

Authors:  C P Charalambous; I Siddique; K Valluripalli; M Kovacevic; P Panose; M Srinivasan; H Marynissen
Journal:  Arch Orthop Trauma Surg       Date:  2006-12-22       Impact factor: 3.067

Review 6.  Outcome of shoulder hemiarthroplasty in acute proximal humeral fractures: a frustrating meta-analysis experience.

Authors:  Stefaan Nijs; Paul Broos
Journal:  Acta Orthop Belg       Date:  2009-08       Impact factor: 0.500

7.  Surgical treatment of three and four-part proximal humeral fractures.

Authors:  Brian D Solberg; Charles N Moon; Dennis P Franco; Guy D Paiement
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

8.  Philos plate fixation for proximal humeral fractures.

Authors:  A A Martinez; J Cuenca; A Herrera
Journal:  J Orthop Surg (Hong Kong)       Date:  2009-04       Impact factor: 1.118

9.  [Early results of treatment of proximal humerus fractures with the PHILOS locking plate].

Authors:  Bülent Kiliç; Mustafa Uysal; Bekir Murat Cinar; Gürkan Ozkoç; Hüseyin Demirörs; Sercan Akpinar
Journal:  Acta Orthop Traumatol Turc       Date:  2008 May-Jul       Impact factor: 1.511

10.  Plating in Proximal Humeral Fractures.

Authors:  Reto Babst; Felix Brunner
Journal:  Eur J Trauma Emerg Surg       Date:  2007-07-31       Impact factor: 3.693

View more
  2 in total

1.  Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus?

Authors:  M A Verdano; E Lunini; A Pellegrini; T Corsini; P Marenghi; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2013-06-08

2.  Surgical Fixation of Three- and Four-Part Proximal Humeral Fractures Using the Proximal Humeral Interlocking System Plate.

Authors:  Ahmed Y Saber; Umar N Said; Abdelmonem H Abdelmonem; Hassan Elsayed; Mohamed Taha; Walid Hussein; Khalid Al-Hashimi; Omar El-Omar; Mohamed Elbeshbeshy
Journal:  Cureus       Date:  2022-05-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.