Literature DB >> 21371058

Development of an implantable myoelectric sensor for advanced prosthesis control.

Daniel R Merrill1, Joseph Lockhart, Phil R Troyk, Richard F Weir, David L Hankin.   

Abstract

Modern hand and wrist prostheses afford a high level of mechanical sophistication, but the ability to control them in an intuitive and repeatable manner lags. Commercially available systems using surface electromyographic (EMG) or myoelectric control can supply at best two degrees of freedom (DOF), most often sequentially controlled. This limitation is partially due to the nature of surface-recorded EMG, for which the signal contains components from multiple muscle sources. We report here on the development of an implantable myoelectric sensor using EMG sensors that can be chronically implanted into an amputee's residual muscles. Because sensing occurs at the source of muscle contraction, a single principal component of EMG is detected by each sensor, corresponding to intent to move a particular effector. This system can potentially provide independent signal sources for control of individual effectors within a limb prosthesis. The use of implanted devices supports inter-day signal repeatability. We report on efforts in preparation for human clinical trials, including animal testing, and a first-in-human proof of principle demonstration where the subject was able to intuitively and simultaneously control two DOF in a hand and wrist prosthesis.
© 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21371058      PMCID: PMC3768255          DOI: 10.1111/j.1525-1594.2011.01219.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

1.  A STATISTICAL STUDY OF 12,000 NEW AMPUTEES.

Authors:  H W GLATTLY
Journal:  South Med J       Date:  1964-11       Impact factor: 0.954

2.  A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control.

Authors:  Abidemi Bolu Ajiboye; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2005-09       Impact factor: 3.802

Review 3.  Upper limb prosthesis use and abandonment: a survey of the last 25 years.

Authors:  Elaine A Biddiss; Tom T Chau
Journal:  Prosthet Orthot Int       Date:  2007-09       Impact factor: 1.895

4.  Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control.

Authors:  Richard Weir; Philip Troyk; Glenn Demichele; Douglas Kerns
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

5.  Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors.

Authors:  Justin J Baker; Erik Scheme; Kevin Englehart; Douglas T Hutchinson; Bradley Greger
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2010-04-08       Impact factor: 3.802

6.  Estimating the prevalence of limb loss in the United States: 2005 to 2050.

Authors:  Kathryn Ziegler-Graham; Ellen J MacKenzie; Patti L Ephraim; Thomas G Travison; Ron Brookmeyer
Journal:  Arch Phys Med Rehabil       Date:  2008-03       Impact factor: 3.966

7.  Implantable myoelectric sensors (IMESs) for intramuscular electromyogram recording.

Authors:  Richard F ff Weir; Phil R Troyk; Glen A DeMichele; Douglas A Kerns; Jack F Schorsch; Huub Maas
Journal:  IEEE Trans Biomed Eng       Date:  2009-01       Impact factor: 4.538

  7 in total
  20 in total

1.  Real-time simultaneous and proportional myoelectric control using intramuscular EMG.

Authors:  Lauren H Smith; Todd A Kuiken; Levi J Hargrove
Journal:  J Neural Eng       Date:  2014-11-14       Impact factor: 5.379

2.  Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles.

Authors:  Christian Cipriani; Jacob L Segil; J Alex Birdwell; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2014-01-21       Impact factor: 3.802

3.  Toward the Bionic Face: A Novel Neuroprosthetic Device Paradigm for Facial Reanimation Consisting of Neural Blockade and Functional Electrical Stimulation.

Authors:  Nate Jowett; Robert E Kearney; Christopher J Knox; Tessa A Hadlock
Journal:  Plast Reconstr Surg       Date:  2019-01       Impact factor: 4.730

4.  Low-power polling mode of the next-generation IMES2 implantable wireless EMG sensor.

Authors:  Glenn A DeMichele; Zhe Hu; Philip R Troyk; Hongnan Chen; Richard F ff Weir
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

5.  Feasibility of a Wireless Implantable Multi-electrode System for High-bandwidth Prosthetic Interfacing: Animal and Cadaver Study.

Authors:  Clemens Gstoettner; Christopher Festin; Cosima Prahm; Konstantin D Bergmeister; Stefan Salminger; Agnes Sturma; Christian Hofer; Michael F Russold; Charla L Howard; Daniel McDonnall; Dario Farina; Oskar C Aszmann
Journal:  Clin Orthop Relat Res       Date:  2022-02-23       Impact factor: 4.755

6.  Myoelectric Control System and Task-Specific Characteristics Affect Voluntary Use of Simultaneous Control.

Authors:  Lauren H Smith; Todd A Kuiken; Levi J Hargrove
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2015-03-06       Impact factor: 3.802

7.  Extrinsic finger and thumb muscles command a virtual hand to allow individual finger and grasp control.

Authors:  J Alexander Birdwell; Levi J Hargrove; Richard F ff Weir; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2014-07-31       Impact factor: 4.538

8.  Real-time myoelectric control of a multi-fingered hand prosthesis using principal components analysis.

Authors:  Giulia C Matrone; Christian Cipriani; Maria Chiara Carrozza; Giovanni Magenes
Journal:  J Neuroeng Rehabil       Date:  2012-06-15       Impact factor: 4.262

Review 9.  Toward higher-performance bionic limbs for wider clinical use.

Authors:  Dario Farina; Ivan Vujaklija; Rickard Brånemark; Anthony M J Bull; Hans Dietl; Bernhard Graimann; Levi J Hargrove; Klaus-Peter Hoffmann; He Helen Huang; Thorvaldur Ingvarsson; Hilmar Bragi Janusson; Kristleifur Kristjánsson; Todd Kuiken; Silvestro Micera; Thomas Stieglitz; Agnes Sturma; Dustin Tyler; Richard F Ff Weir; Oskar C Aszmann
Journal:  Nat Biomed Eng       Date:  2021-05-31       Impact factor: 25.671

10.  Muscle activation patterns during walking from transtibial amputees recorded within the residual limb-prosthetic interface.

Authors:  Stephanie Huang; Daniel P Ferris
Journal:  J Neuroeng Rehabil       Date:  2012-08-10       Impact factor: 4.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.