Literature DB >> 20378481

Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors.

Justin J Baker1, Erik Scheme, Kevin Englehart, Douglas T Hutchinson, Bradley Greger.   

Abstract

A rhesus monkey was trained to perform individuated and combined finger flexions of the thumb, index, and middle finger. Nine implantable myoelectric sensors (IMES) were then surgically implanted into the finger muscles of the monkey's forearm, without any adverse effects over two years postimplantation. Using an inductive link, EMG was wirelessly recorded from the IMES as the monkey performed a finger flexion task. The EMG from the different IMES implants showed very little cross correlation. An offline parallel linear discriminant analysis (LDA) based algorithm was used to decode finger activity based on features extracted from continuously presented frames of recorded EMG. The offline parallel LDA was run on intraday sessions as well as on sessions where the algorithm was trained on one day and tested on following days. The performance of the algorithm was evaluated continuously by comparing classification output by the algorithm to the current state of the finger switches. The algorithm detected and classified seven different finger movements, including individual and combined finger flexions, and a no-movement state (chance performance = 12.5%) . When the algorithm was trained and tested on data collected the same day, the average performance was 43.8+/-3.6% n=10. When the training-testing separation period was five months, the average performance of the algorithm was 46.5+/-3.4% n=8. These results demonstrated that using EMG recorded and wirelessly transmitted by IMES offers a promising approach for providing intuitive, dexterous control of artificial limbs where human patients have sufficient, functional residual muscle following amputation.

Entities:  

Mesh:

Year:  2010        PMID: 20378481     DOI: 10.1109/TNSRE.2010.2047590

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  18 in total

1.  Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles.

Authors:  Christian Cipriani; Jacob L Segil; J Alex Birdwell; Richard F ff Weir
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2014-01-21       Impact factor: 3.802

2.  Comparison of surface and intramuscular EMG pattern recognition for simultaneous wrist/hand motion classification.

Authors:  Lauren H Smith; Levi J Hargrove
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

3.  Development of an implantable myoelectric sensor for advanced prosthesis control.

Authors:  Daniel R Merrill; Joseph Lockhart; Phil R Troyk; Richard F Weir; David L Hankin
Journal:  Artif Organs       Date:  2011-03-03       Impact factor: 3.094

4.  Motor unit drive: a neural interface for real-time upper limb prosthetic control.

Authors:  Michael D Twardowski; Serge H Roy; Zhi Li; Paola Contessa; Gianluca De Luca; Joshua C Kline
Journal:  J Neural Eng       Date:  2018-10-24       Impact factor: 5.379

5.  Decoding of grasping information from neural signals recorded using peripheral intrafascicular interfaces.

Authors:  Silvestro Micera; Paolo M Rossini; Jacopo Rigosa; Luca Citi; Jacopo Carpaneto; Stanisa Raspopovic; Mario Tombini; Christian Cipriani; Giovanni Assenza; Maria C Carrozza; Klaus-Peter Hoffmann; Ken Yoshida; Xavier Navarro; Paolo Dario
Journal:  J Neuroeng Rehabil       Date:  2011-09-05       Impact factor: 4.262

Review 6.  Flexible Electronics and Devices as Human-Machine Interfaces for Medical Robotics.

Authors:  Wenzheng Heng; Samuel Solomon; Wei Gao
Journal:  Adv Mater       Date:  2022-02-25       Impact factor: 32.086

7.  Classification of simultaneous movements using surface EMG pattern recognition.

Authors:  Aaron J Young; Lauren H Smith; Elliott J Rouse; Levi J Hargrove
Journal:  IEEE Trans Biomed Eng       Date:  2012-12-10       Impact factor: 4.538

Review 8.  On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson; Jean Delbeke
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

Review 9.  Toward higher-performance bionic limbs for wider clinical use.

Authors:  Dario Farina; Ivan Vujaklija; Rickard Brånemark; Anthony M J Bull; Hans Dietl; Bernhard Graimann; Levi J Hargrove; Klaus-Peter Hoffmann; He Helen Huang; Thorvaldur Ingvarsson; Hilmar Bragi Janusson; Kristleifur Kristjánsson; Todd Kuiken; Silvestro Micera; Thomas Stieglitz; Agnes Sturma; Dustin Tyler; Richard F Ff Weir; Oskar C Aszmann
Journal:  Nat Biomed Eng       Date:  2021-05-31       Impact factor: 25.671

10.  BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms.

Authors:  Max Ortiz-Catalan; Rickard Brånemark; Bo Håkansson
Journal:  Source Code Biol Med       Date:  2013-04-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.