Literature DB >> 21370637

Use of a portable point-of-care (Vetscan VS2) biochemical analyzer for measuring plasma biochemical levels in free-living loggerhead sea turtles (Caretta caretta).

Adrienne Atkins1, Elliott Jacobson, Jorge Hernandez, Alan B Bolten, Xiaomin Lu.   

Abstract

The agreement of plasma biochemical values between a portable point-of-care analyzer and a veterinary diagnostic laboratory in wild caught loggerhead sea turtles (Caretta caretta) was tested. Banked plasma samples from presumptively healthy turtles collected for an on-going project that involves health assessments of sea turtles from the southeast coast of Florida were used for this study. Plasma biochemical analytes evaluated included albumin, aspartate aminotransferase, calcium, creatinine kinase, glucose, potassium, sodium, phosphorus, total protein, bile acids, and uric acid. Paired plasma samples were run in duplicates and compared between a point-of-care analyzer and a veterinary diagnostic laboratory (VDL). Overall, the precision was greater as measured within the point-of-care analyzer than within the VDL analyzer; however, agreement between the two testing methods was poor. Correlation (r(i)) between the two analyzers was high for many of the analytes; however, the small P-value and high relative error led to the conclusion that the two analyzers were not equivalent. In addition, a comparison was made between the biochemical values obtained at the time of collection and after storage in an ultralow freezer for up to 2.5 yr. Plasma samples analyzed at the VDL, performed on different models of the same machine, were significantly lower after storage than those acquired near the time of collection. This difference was most likely because of sample degradation that occurred during storage. Whereas, statistically significant differences were observed within and between the analyzers, many of these differences may not be clinically significant. Even though this study has a few limitations, including a technical malfunction and the use of two different diagnostic laboratories, biochemical values for the given population are reported when using both a portable system and a diagnostic laboratory. Based on the findings of this study, the authors believe that point-of-care analyzers can provide valuable adjunctive diagnostics, especially in field situations.

Entities:  

Mesh:

Year:  2010        PMID: 21370637     DOI: 10.1638/2009-0023.1

Source DB:  PubMed          Journal:  J Zoo Wildl Med        ISSN: 1042-7260            Impact factor:   0.776


  8 in total

1.  Venous blood gases, plasma biochemistry, and hematology of wild-caught common chameleons (Chamaeleo chamaeleon).

Authors:  David Eshar; Melanie Ammersbach; Boaz Shacham; Gad Katzir; Hugues Beaufrère
Journal:  Can J Vet Res       Date:  2018-04       Impact factor: 1.310

2.  Reference Intervals for Plasma Biochemical Variables by Point-of-Care Testing in Captive Black-tailed Prairie Dogs (Cynomys ludovicianus).

Authors:  David Eshar; Sara M Gardhouse; Diana Schwartz; Hugues Beaufrere
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-09-12       Impact factor: 1.232

3.  Hematology and biochemistry of critically endangered radiated tortoises (Astrochelys radiata): Reference intervals in previously confiscated subadults and variability based on common techniques.

Authors:  Maris Brenn-White; Bonnie L Raphael; Ny Aina Tiana Rakotoarisoa; Sharon L Deem
Journal:  PLoS One       Date:  2022-03-14       Impact factor: 3.240

4.  Assessment of ground transportation stress in juvenile Kemp's ridley sea turtles (Lepidochelys kempii).

Authors:  Kathleen E Hunt; Charles J Innis; Adam E Kennedy; Kerry L McNally; Deborah G Davis; Elizabeth A Burgess; Constance Merigo
Journal:  Conserv Physiol       Date:  2016-03-01       Impact factor: 3.079

5.  Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.

Authors:  Lauren J Stoot; Nicholas A Cairns; Felicia Cull; Jessica J Taylor; Jennifer D Jeffrey; Félix Morin; John W Mandelman; Timothy D Clark; Steven J Cooke
Journal:  Conserv Physiol       Date:  2014-04-04       Impact factor: 3.079

6.  Predictive Blood Chemistry Parameters for Pansteatitis-Affected Mozambique Tilapia (Oreochromis mossambicus).

Authors:  John A Bowden; Theresa M Cantu; Robert W Chapman; Stephen E Somerville; Matthew P Guillette; Hannes Botha; Andre Hoffman; Wilmien J Luus-Powell; Willem J Smit; Jeffrey Lebepe; Jan Myburgh; Danny Govender; Jonathan Tucker; Ashley S P Boggs; Louis J Guillette
Journal:  PLoS One       Date:  2016-04-26       Impact factor: 3.240

7.  Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser.

Authors:  Matthew T Hamilton; John W Finger; Megan E Winzeler; Tracey D Tuberville
Journal:  Conserv Physiol       Date:  2016-01-08       Impact factor: 3.079

8.  Evaluation of the accuracy of an electronic point-of-care analyzer to quantify blood creatinine concentration in goats.

Authors:  Melanie J Boileau; Leslie Wagner; Jared D Taylor
Journal:  J Vet Intern Med       Date:  2021-02-24       Impact factor: 3.333

  8 in total