Trimble GX200 and Riegl LMS-Z390i sensor self-calibration.

D González-Aguilera1, P Rodríguez-Gonzálvez, J Armesto, P Arias.   

Abstract

This paper aims to establish and develop a calibration model for two time-of-flight terrestrial laser scanners (TLS): Trimble GX200 and Riegl LMS-Z390i. In particular, the study focuses on measurement errors and systematic instrumental errors to compile an error model for TLS. An iterative and robust least squares procedure is developed to compute internal calibration parameters together with a TLS data set geo-reference in an external reference system. To this end, a calibration field is designed that performs as an experimental platform that tests the different laser scanner methods. The experimental results show the usefulness and potential of this approach, especially when high-precision measurements are requires.

Entities:  

Mesh:

Year:  2011        PMID: 21369089     DOI: 10.1364/OE.19.002676

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  Determining geometric error model parameters of a terrestrial laser scanner through Two-face, Length-consistency, and Network methods.

Authors:  Ling Wang; Bala Muralikrishnan; Prem Rachakonda; Daniel Sawyer
Journal:  Meas Sci Technol       Date:  2017-05-09       Impact factor: 2.046

2.  Performance Evaluation of Terrestrial Laser Scanners - A Review.

Authors:  Bala Muralikrishnan
Journal:  Meas Sci Technol       Date:  2021       Impact factor: 2.046

3.  High-Accuracy Self-Calibration for Smart, Optical Orbiting Payloads Integrated with Attitude and Position Determination.

Authors:  Jin Li; Fei Xing; Daping Chu; Zilong Liu
Journal:  Sensors (Basel)       Date:  2016-07-27       Impact factor: 3.576

4.  Improvements to and comparison of static terrestrial LiDAR self-calibration methods.

Authors:  Jacky C K Chow; Derek D Lichti; Craig Glennie; Preston Hartzell
Journal:  Sensors (Basel)       Date:  2013-05-31       Impact factor: 3.576

5.  Towards System Calibration of Panoramic Laser Scanners from a Single Station.

Authors:  Tomislav Medić; Christoph Holst; Heiner Kuhlmann
Journal:  Sensors (Basel)       Date:  2017-05-17       Impact factor: 3.576

6.  Optical focal plane based on MEMS light lead-in for geometric camera calibration.

Authors:  Jin Li; Zilong Liu
Journal:  Microsyst Nanoeng       Date:  2017-11-06       Impact factor: 7.127