Literature DB >> 21365422

Total arch replacement and open stent graft implantation using a newly developed stent graft: report of a case.

Akira Sezai1, Kenji Akiyama, Mitsumasa Hata, Tetsuya Niino, Isamu Yoshitake, Shinji Wakui, Kishu Fujita, Ayako Takasaka, Hideomi Kawachi, Tomohiko Murakami, Kazutomo Minami.   

Abstract

We experienced a case in which a total arch replacement and an open stent implantation were performed for a distal aortic arch aneurysm using a newly developed stent graft (Ube CL-0201; Ube Medical, Tokyo, Japan). This novel stent graft is composed of a woven polyester graft and a nickel-titanium alloy stent, and has been under evaluation in clinical trials at four institutions in Japan, including our hospital, since 2008. The patient was weaned from the respirator on the day after surgery, and 9 months have passed since the surgery with no complications. A follow-up computed tomography scan showed that the stent part was sufficiently open, and no complications, such as an endoleak, have been observed.

Entities:  

Mesh:

Year:  2011        PMID: 21365422     DOI: 10.1007/s00595-010-4264-6

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  7 in total

1.  One-stage repair with a new integrated stent-Dacron prosthesis for type B aortic dissection.

Authors:  Aristotelis Panos; Spyros Kalakonas; Elefterios Chouliaras; Gregory Khatchatourov
Journal:  Ann Thorac Surg       Date:  2007-04       Impact factor: 4.330

2.  Long-term results of the open stent-grafting technique for extended aortic arch disease.

Authors:  Kazuo Shimamura; Toru Kuratani; Goro Matsumiya; Masaaki Kato; Yukitoshi Shirakawa; Hiroshi Takano; Noriyuki Ohta; Yoshiki Sawa
Journal:  J Thorac Cardiovasc Surg       Date:  2008-06       Impact factor: 5.209

3.  Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen.

Authors:  Naomichi Uchida; Hidenori Shibamura; Akira Katayama; Norimitsu Shimada; Miwa Sutoh
Journal:  Eur J Cardiothorac Surg       Date:  2008-11-08       Impact factor: 4.191

4.  New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft.

Authors:  M Kato; K Ohnishi; M Kaneko; T Ueda; D Kishi; T Mizushima; H Matsuda
Journal:  Circulation       Date:  1996-11-01       Impact factor: 29.690

5.  Complications of open stent-graft in treatment of aortic dissection.

Authors:  Shang Dong Xu; Bao Zhong Yang; Zhan Ming Fan; Fang Jiong Huang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2008-09-29

6.  Combined surgical and endovascular repair of complex aortic pathologies with a new hybrid prosthesis.

Authors:  Michael Gorlitzer; Gabriel Weiss; Markus Thalmann; Gerard Mertikian; Wojciech Wislocki; Johann Meinhart; Ferdinand Waldenberger; Martin Grabenwoger
Journal:  Ann Thorac Surg       Date:  2007-12       Impact factor: 4.330

7.  Transaortic stent grafting for distal arch aneurysm with antegrade and retrograde extracorporeal circulation.

Authors:  K Akiyama; K-I Nakata; S Kasiwazaki; S Fukushima
Journal:  Thorac Cardiovasc Surg       Date:  2009-05-20       Impact factor: 1.827

  7 in total
  2 in total

1.  Concomitant aortic valve and ascending aorta replacement with moderate hypothermic circulatory arrest to treat an aortic bicuspid valve with post-stenotic dilatation.

Authors:  Mitsumasa Hata; Kenji Akiyama; Shinji Wakui; Ayako Takasaka; Motomi Shiono
Journal:  Surg Today       Date:  2012-06-04       Impact factor: 2.549

2.  Open-stent grafting with a GORE TAG thoracic endoprosthesis for an extended severely atheromatous thoracic aortic aneurysm: report of a case.

Authors:  Takashi Igarashi; Shinya Takase; Hirono Satokawa; Yukitoki Misawa; Hiroki Wakamatsu; Yoshiyuki Sato; Hiroyuki Kurosawa; Yuuki Seto; Eitoshi Tsuboi; Hitoshi Yokoyama
Journal:  Surg Today       Date:  2012-09-16       Impact factor: 2.549

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.