| Literature DB >> 21365422 |
Akira Sezai1, Kenji Akiyama, Mitsumasa Hata, Tetsuya Niino, Isamu Yoshitake, Shinji Wakui, Kishu Fujita, Ayako Takasaka, Hideomi Kawachi, Tomohiko Murakami, Kazutomo Minami.
Abstract
We experienced a case in which a total arch replacement and an open stent implantation were performed for a distal aortic arch aneurysm using a newly developed stent graft (Ube CL-0201; Ube Medical, Tokyo, Japan). This novel stent graft is composed of a woven polyester graft and a nickel-titanium alloy stent, and has been under evaluation in clinical trials at four institutions in Japan, including our hospital, since 2008. The patient was weaned from the respirator on the day after surgery, and 9 months have passed since the surgery with no complications. A follow-up computed tomography scan showed that the stent part was sufficiently open, and no complications, such as an endoleak, have been observed.Entities:
Mesh:
Year: 2011 PMID: 21365422 DOI: 10.1007/s00595-010-4264-6
Source DB: PubMed Journal: Surg Today ISSN: 0941-1291 Impact factor: 2.549