Literature DB >> 21364264

14C autoradiography with an energy-sensitive silicon pixel detector.

M Esposito1, G Mettivier, P Russo.   

Abstract

The first performance tests are presented of a carbon-14 ((14)C) beta-particle digital autoradiography system with an energy-sensitive hybrid silicon pixel detector based on the Timepix readout circuit. Timepix was developed by the Medipix2 Collaboration and it is similar to the photon-counting Medipix2 circuit, except for an added time-based synchronization logic which allows derivation of energy information from the time-over-threshold signal. This feature permits direct energy measurements in each pixel of the detector array. Timepix is bump-bonded to a 300 µm thick silicon detector with 256 × 256 pixels of 55 µm pitch. Since an energetic beta-particle could release its kinetic energy in more than one detector pixel as it slows down in the semiconductor detector, an off-line image analysis procedure was adopted in which the single-particle cluster of hit pixels is recognized; its total energy is calculated and the position of interaction on the detector surface is attributed to the centre of the charge cluster. Measurements reported are detector sensitivity, (4.11 ± 0.03) × 10(-3) cps mm(-2) kBq(-1) g, background level, (3.59 ± 0.01) × 10(-5) cps mm(-2), and minimum detectable activity, 0.0077 Bq. The spatial resolution is 76.9 µm full-width at half-maximum. These figures are compared with several digital imaging detectors for (14)C beta-particle digital autoradiography.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21364264     DOI: 10.1088/0031-9155/56/7/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Performance evaluation of 18 F radioluminescence microscopy using computational simulation.

Authors:  Qian Wang; Debanti Sengupta; Tae Jin Kim; Guillem Pratx
Journal:  Med Phys       Date:  2017-04-17       Impact factor: 4.071

2.  Autoradiography imaging in targeted alpha therapy with Timepix detector.

Authors:  Ruqaya A L Darwish; Alexander Hugo Staudacher; Eva Bezak; Michael Paul Brown
Journal:  Comput Math Methods Med       Date:  2015-01-22       Impact factor: 2.238

3.  Multiscale Framework for Imaging Radiolabeled Therapeutics.

Authors:  Arutselvan Natarajan; Silvan Türkcan; Sanjiv S Gambhir; Guillem Pratx
Journal:  Mol Pharm       Date:  2015-11-05       Impact factor: 4.939

Review 4.  Subcellular Targeting of Theranostic Radionuclides.

Authors:  Bas M Bavelaar; Boon Q Lee; Martin R Gill; Nadia Falzone; Katherine A Vallis
Journal:  Front Pharmacol       Date:  2018-09-04       Impact factor: 5.988

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.