Literature DB >> 21360748

Test-retest reliability and reproducibility of short-echo-time spectroscopic imaging of human brain at 3T.

Charles Gasparovic1, Edward J Bedrick, Andrew R Mayer, Ronald A Yeo, Hongji Chen, Eswar Damaraju, Vince D Calhoun, Rex E Jung.   

Abstract

A 1H magnetic resonance spectroscopic imaging study at 3T and short echo time was conducted to evaluate both the reproducibility, as measured by the interscan coefficient of variation (CV), and test-retest reliability, as measured by the intraclass correlation coefficient (ICC), of measurements of glutamate (Glu), combined glutamate and glutamine (Glx), myo-inositol (mI), N-acetylaspartate, creatine, and choline in 21 healthy subjects. The effect of partial volume correction on these measures and the relationship of reproducibility and reliability to data quality were also examined. A 1H magnetic resonance spectroscopic imaging slice was prescribed above the lateral ventricles and single repeat scans were performed within 30 min to minimize physiologic variability. Interscan CVs based on all the voxels varied from 0.05 to 0.07 for N-acetylaspartate, creatine, and choline to 0.10-0.13 for mI, Glu, and Glx. Findings on the reproducibility of gray and white matter estimates of N-acetylaspartate, creatine, and choline are consistent with previous studies using longer echo times, with CVs in the range of 0.02-0.04 and ICC in the range of 0.65-0.90. CVs for Glu, Glx, and mI are much lower than reported in previous studies at 1.5 T, while white matter mI (CV=0.04, ICC=0.93) and gray matter Glx (CV=0.04, ICC=0.68) demonstrated both high reproducibility and test-retest reliability.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21360748      PMCID: PMC3130105          DOI: 10.1002/mrm.22858

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Quantitation of simulated short echo time 1H human brain spectra by LCModel and AMARES.

Authors:  Martin Kanowski; Jörn Kaufmann; Jürgen Braun; Johannes Bernarding; Claus Tempelmann
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

Review 2.  Issues of spectral quality in clinical 1H-magnetic resonance spectroscopy and a gallery of artifacts.

Authors:  Roland Kreis
Journal:  NMR Biomed       Date:  2004-10       Impact factor: 4.044

3.  Robust analysis of short echo time (1)H MRSI of human brain.

Authors:  X P Zhu; K Young; A Ebel; B J Soher; L Kaiser; G Matson; W M Weiner; N Schuff
Journal:  Magn Reson Med       Date:  2006-03       Impact factor: 4.668

4.  Comparative reliability of proton spectroscopy techniques designed to improve detection of J-coupled metabolites.

Authors:  Paul Gerald Mullins; Hongji Chen; Jing Xu; Arvind Caprihan; Charles Gasparovic
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

5.  Automatic repositioning of MRSI voxels in longitudinal studies: impact on reproducibility of metabolite concentration measurements.

Authors:  Eva-Maria Ratai; Ileana Hancu; Daniel J Blezek; Katherine W Turk; Elkan Halpern; R Gilberto González
Journal:  J Magn Reson Imaging       Date:  2008-05       Impact factor: 4.813

6.  Reproducibility of proton MR spectroscopic imaging findings.

Authors:  G Tedeschi; A Bertolino; G Campbell; A S Barnett; J H Duyn; P K Jacob; C T Moonen; J R Alger; G Di Chiro
Journal:  AJNR Am J Neuroradiol       Date:  1996 Nov-Dec       Impact factor: 3.825

7.  Arterial spin-labeling and MR spectroscopy in the differentiation of gliomas.

Authors:  S Chawla; S Wang; R L Wolf; J H Woo; J Wang; D M O'Rourke; K D Judy; M S Grady; E R Melhem; H Poptani
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  Three-dimensional J-resolved H-1 magnetic resonance spectroscopic imaging of volunteers and patients with brain tumors at 3T.

Authors:  Yan Li; Albert P Chen; Jason C Crane; Susan M Chang; Daniel B Vigneron; Sarah J Nelson
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

9.  A comparative study of myo-inositol quantification using LCmodel at 1.5 T and 3.0 T with 3 D 1H proton spectroscopic imaging of the human brain.

Authors:  Radhika Srinivasan; Daniel Vigneron; Napapon Sailasuta; Ralph Hurd; Sarah Nelson
Journal:  Magn Reson Imaging       Date:  2004-05       Impact factor: 2.546

10.  Reproducibility study of whole-brain 1H spectroscopic imaging with automated quantification.

Authors:  Meng Gu; Dong-Hyun Kim; Dirk Mayer; Edith V Sullivan; Adolf Pfefferbaum; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

View more
  28 in total

1.  Investigation of long-term reproducibility of intrinsic connectivity network mapping: a resting-state fMRI study.

Authors:  Y-h Chou; L P Panych; C C Dickey; J R Petrella; N-k Chen
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

2.  Data-Driven and Predefined ROI-Based Quantification of Long-Term Resting-State fMRI Reproducibility.

Authors:  Xiaomu Song; Lawrence P Panych; Nan-Kuei Chen
Journal:  Brain Connect       Date:  2015-11-18

3.  Neurochemical changes within human early blind occipital cortex.

Authors:  K E Weaver; T L Richards; M Saenz; H Petropoulos; I Fine
Journal:  Neuroscience       Date:  2013-08-14       Impact factor: 3.590

4.  Longitudinal inter- and intra-individual human brain metabolic quantification over 3 years with proton MR spectroscopy at 3 T.

Authors:  Ivan I Kirov; Ilena C George; Nikhil Jayawickrama; James S Babb; Nissa N Perry; Oded Gonen
Journal:  Magn Reson Med       Date:  2011-06-07       Impact factor: 4.668

5.  Reproducibility and reliability of short-TE whole-brain MR spectroscopic imaging of human brain at 3T.

Authors:  Xiao-Qi Ding; Andrew A Maudsley; Mohammad Sabati; Sulaiman Sheriff; Paulo R Dellani; Heinrich Lanfermann
Journal:  Magn Reson Med       Date:  2014-03-26       Impact factor: 4.668

6.  Glutamatergic and Neuronal Dysfunction in Gray and White Matter: A Spectroscopic Imaging Study in a Large Schizophrenia Sample.

Authors:  Juan R Bustillo; Thomas Jones; Hongji Chen; Nicholas Lemke; Christopher Abbott; Clifford Qualls; Shannon Stromberg; Jose Canive; Charles Gasparovic
Journal:  Schizophr Bull       Date:  2017-05-01       Impact factor: 9.306

7.  Reproducibility of phase rotation stimulated echo acquisition mode at 3T in schizophrenia: Emphasis on glutamine.

Authors:  Juan R Bustillo; Nathan Rediske; Thomas Jones; Laura M Rowland; Christopher Abbott; S Andrea Wijtenburg
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

8.  Elucidating Metabolic Maturation in the Healthy Fetal Brain Using 1H-MR Spectroscopy.

Authors:  I E Evangelou; A J du Plessis; G Vezina; R Noeske; C Limperopoulos
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-24       Impact factor: 3.825

9.  The long-term effect of erythropoiesis stimulating agents given to preterm infants: a proton magnetic resonance spectroscopy study on neurometabolites in early childhood.

Authors:  Charles Gasparovic; Arvind Caprihan; Ronald A Yeo; John Phillips; Jean R Lowe; Richard Campbell; Robin K Ohls
Journal:  Pediatr Radiol       Date:  2018-01-15

10.  High-resolution 1 H-MRSI of the brain using short-TE SPICE.

Authors:  Chao Ma; Fan Lam; Qiang Ning; Curtis L Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2016-02-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.