Literature DB >> 21359573

An ultra-sensitive online SPE-LC-MS/MS method for the quantification of levonorgestrel released from intrauterine devices.

Christina Moser1, Andreas Gschliesser, Verena Mattle, Ludwig Wildt, Andrea Griesmacher, Christoph Seger.   

Abstract

A selective and sensitive liquid chromatography-tandem mass spectrometry method for the determination of very low levonorgestrel (D-(-)-norgestrel) serum levels such as those found in patients using levonorgestrel-releasing intrauterine devices (IUDs) was developed. To achieve the sub-nanomolar sensitivity needed to measure such serum levels, a diethyl ether extraction sample preparation protocol was applied prior to the online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) assay. Analyte quantification from the selected reaction monitoring experiments relied on the use of sixfold deuterated norgestrel as internal standard. The final method was linear up to 1.50 ng/ml with a lower limit of quantification (LLOQ) of 0.05 ng/ml. It was found to be precise and accurate with imprecision <8% and bias <6% assessed at three control levels. Total analyte recovery measured in patient pools at three concentration levels was found to exceed 92%. Matrix interferences were excluded by post-column analyte infusion experiments. As a proof of concept, a set of IUD patient serum samples was screened for their levonorgestrel content. A total of 97.5% (n = 94) of the samples did show serum levels exceeding the LLOQ, proving the applicability of the assay in relevant clinical cohorts. This method must not be used for diagnostic or therapeutic purposes, since it did not undergo formal performance evaluation in the sense of the in vitro diagnostic directive (98/79/EG) of the European community.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21359573     DOI: 10.1007/s00216-011-4790-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

1.  Development, validation and utilization of a highly sensitive LC-MS/MS method for quantification of levonorgestrel released from a subdermal implant in human plasma.

Authors:  Lauren R Cirrincione; Sujan Dilly Penchala; Kimberly K Scarsi; Anthony T Podany; Lee C Winchester; David J Back; Saye H Khoo; Courtney V Fletcher; Marco Siccardi; Laura J Else
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2018-03-12       Impact factor: 3.205

2.  RP-HPLC method validation for fast extraction and quantification of Levonorgestrel drug from silicone based intrauterine device intended for in-process and finished formulation.

Authors:  Midhu George Veeran; Karthikeyan C; Bharaniraja B; Diksha Painuly; Abi Santhosh Aprem
Journal:  Daru       Date:  2021-05-01       Impact factor: 3.117

3.  Determination of Ethinyl Estradiol and Levonorgestrel in Human Plasma with Prednisone as Internal Standard Using Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Yahdiana Harahap; Devina Devina; Harmita Harmita
Journal:  J Pharm Bioallied Sci       Date:  2019 Jul-Sep

4.  Models and methods to characterise levonorgestrel release from intradermally administered contraceptives.

Authors:  Adnan Al Dalaty; Benedetta Gualeni; Sion A Coulman; James C Birchall
Journal:  Drug Deliv Transl Res       Date:  2021-12-03       Impact factor: 4.617

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.