Literature DB >> 21355982

Randomized controlled, multicentre clinical trial comparing a dual-probe ultrasonic lithotrite with a single-probe lithotrite for percutaneous nephrolithotomy.

Amy E Krambeck1, Nicole L Miller1, Mitchell R Humphreys1, Stephen Y Nakada1, John D Denstedt1, Hassan Razvi1, Glenn M Preminger1, Robert B Nadler1, Brian R Matlaga1, Ryan F Paterson1, Ben H Chew1, Larry C Munch1, Shelly E Handa1, James E Lingeman1.   

Abstract

OBJECTIVES: • To compare the Cyberwand (Gyrus/ACMI, Southborough, MA, USA), a dual-probe ultrasonic lithotrite, with a single-probe ultrasonic lithotrite. • The Cyberwand incorporates coaxial high- and low-frequency ultrasonic probes that work synergistically. PATIENTS AND METHODS: • An institutional review board-approved, multicentre, randomized controlled trial to compare the Cyberwand to the Olympus LUS-II (Olympus America, Inc., Melville, NY, USA) single-probe lithotrite was performed. • Patients undergoing a percutaneous nephrolithotomy (PCNL) with a target stone > 2 cm in diameter were eligible for the study. • The primary outcome was the time to removal of the targeted stone.
RESULTS: • A total of 57 PCNLs were performed after randomization: 25 Cyberwand and 32 LUS-II. • There was no difference (P > 0.05) observed between the two devices for target stone surface area (Cyberwand 526.6 cm³ vs LUS-II 540.1 cm³), time to clearance of target stone (Cyberwand 15.8 min vs LUS-II 14.2 min) and target stone clearance rate (Cyberwand 61.9 mm²/min vs LUS-II 75.8 mm²/min). • Of the patients with stone analysis, hard stones (calcium oxalate monohydrate, brushite and cystine) were noted in 14 (56.0%) of the 25 Cyberwand and 18 (62.1%) of the 29 LUS-II patients. • Fifteen of the 25 (60.0%) Cyberwand and 20 of the 32 (62.5%) LUS-II patients were stone-free after the initial PCNL. • Those patients not rendered stone-free went on to receive a secondary PCNL. • Device malfunction occurred in eight of 25(32.0%) Cyberwand and five of 32 (15.6%) LUS II patients. • Complications were similar in both treatment groups.
CONCLUSION: • No appreciable difference between the dual-probe Cyberwand and the standard ultrasonic Olympus LUS-II lithotrites can be identified.
© 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

Entities:  

Mesh:

Year:  2010        PMID: 21355982     DOI: 10.1111/j.1464-410X.2010.09567.x

Source DB:  PubMed          Journal:  BJU Int        ISSN: 1464-4096            Impact factor:   5.588


  8 in total

Review 1.  Kidney stones.

Authors:  Timothy Y Tseng; Glenn M Preminger
Journal:  BMJ Clin Evid       Date:  2011-11-10

2.  Comparison of stone elimination capacity and drilling speed of endoscopic clearance lithotripsy devices.

Authors:  Maximilian Eisel; Markus J Bader; Frank Strittmatter; Udo Nagele; Christian G Stief; Thomas Pongratz; Ronald Sroka
Journal:  World J Urol       Date:  2020-04-10       Impact factor: 4.226

3.  Stone clearance times with mini-percutaneous nephrolithotomy: Comparison of a 1.5 mm ballistic/ultrasonic mini-probe vs. laser.

Authors:  Brennan Timm; Matthew Farag; Niall F Davis; David Webb; David Angus; Andrew Troy; Damien Bolton; Gregory S Jack
Journal:  Can Urol Assoc J       Date:  2021-01       Impact factor: 1.862

Review 4.  Intracorporeal lithotripsy.

Authors:  Peter Alken
Journal:  Urolithiasis       Date:  2017-12-04       Impact factor: 3.436

5.  Consultation on kidney stones, Copenhagen 2019: lithotripsy in percutaneous nephrolithotomy.

Authors:  Tomas Andri Axelsson; Cecilia Cracco; Mahesh Desai; Mudhar Nazar Hasan; Thomas Knoll; Emanuele Montanari; Daniel Pérez-Fentes; Michael Straub; Kay Thomas; James C Williams; Marianne Brehmer; Palle J S Osther
Journal:  World J Urol       Date:  2020-07-29       Impact factor: 4.226

6.  Comparison of ultrasonic and pneumatic intracorporeal lithotripsy techniques during percutaneous nephrolithotomy.

Authors:  Tolga Karakan; Akif Diri; Ahmet Metin Hascicek; Berat Cem Ozgur; Serkan Ozcan; Muzaffer Eroglu
Journal:  ScientificWorldJournal       Date:  2013-08-18

7.  An ex-vivo assessment of a new single probe triple modality (Trilogy) lithotripter.

Authors:  Charles Joseph O'Connor; Donnacha Hogan; Lee Chien Yap; Louise Lyons; Derek Barry Hennessey
Journal:  World J Urol       Date:  2022-08-24       Impact factor: 3.661

Review 8.  Recent advancement or less invasive treatment of percutaneous nephrolithotomy.

Authors:  Bum Soo Kim
Journal:  Korean J Urol       Date:  2015-09-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.