Outcome of patients after transcatheter aortic valve embolization.

Edgar L W Tay1, Ronen Gurvitch, Namal Wijeysinghe, Fabian Nietlispach, Jonathon Leipsic, David A Wood, Gerald Yong, Anson Cheung, Jian Ye, Samuel V Lichtenstein, Ronald Carere, Christopher Thompson, John G Webb.   

Abstract

OBJECTIVES: This study aims to assess the mid- to long-term follow-up of patients after valve embolization at the time of transcatheter aortic valve implantation (TAVI).
BACKGROUND: Transcatheter heart valve (THV) embolization is a rare but serious complication during TAVI. Although various techniques have been developed to manage acute complications and reduce periprocedural morbidity/mortality, long-term clinical and hemodynamic consequences after these events are unknown.
METHODS: Patients who developed THV embolization after TAVI were prospectively assessed. Clinical and echocardiographic characteristics were recorded at baseline and after successful TAVI/surgical aortic valve replacement. The THV migration and strut fractures/degeneration were assessed by computed tomography.
RESULTS: A total of 7 patients had THV embolization, all of which occurred immediately after valve deployment. The embolized THV was repositioned in the aortic arch proximal to the left subclavian artery (n = 2), immediately distal to the left subclavian artery (n = 2), and in the abdominal aorta (n = 3). A second THV was implanted successfully at the same sitting in 4 patients and at the time of a second procedure in 2 patients. Elective conventional aortic valve replacement was performed in 1 patient. Median follow-up was 1,085 days. One patient died during follow-up from an unrelated cause. The remaining 6 survivors were in New York Heart Association functional class I or II at final follow-up. Mid-term computed tomography follow-up (n = 4,591 to 1,548 days) showed that the leaflets of the embolized THV remain open in all phases of the cardiac cycle. There was also no strut fracture or migration of these valves.
CONCLUSIONS: Clinical outcomes remain good when THV embolization is managed effectively. There are no apparent hemodynamic consequences of a second valve placed in the series. These embolized valves remain in a stable position with no evidence of strut fractures at mid-term follow-up.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21349463     DOI: 10.1016/j.jcin.2010.10.010

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  15 in total

1.  Migration of the transcatheter valve into the left ventricle.

Authors:  Christopher Cao; Su C Ang; Michael P Vallely; Martin Ng; Mark Adams; Michael Wilson
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 2.  Transcatheter aortic valve implantation.

Authors:  Yoshiki Sawa
Journal:  Surg Today       Date:  2014-05-20       Impact factor: 2.549

Review 3.  Aortic annulus sizing in stenotic bicommissural non-raphe-type bicuspid aortic valves: reconstructing a three-dimensional structure using only two hinge points.

Authors:  Antonio H Frangieh; Jonathan Michel; Oliver Deutsch; Michael Joner; Costanza Pellegrini; Tobias Rheude; Sabine Bleiziffer; Albert Markus Kasel
Journal:  Clin Res Cardiol       Date:  2018-06-14       Impact factor: 5.460

4.  Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Authors:  Riccardo Faletti; Marco Gatti; Stefano Salizzoni; Laura Bergamasco; Rodolfo Bonamini; Domenica Garabello; Walter Grosso Marra; Michele La Torre; Mara Morello; Simona Veglia; Paolo Fonio; Mauro Rinaldi
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-27       Impact factor: 2.357

5.  Novel use of an apical-femoral wire rail to assist with transfemoral transcatheter aortic valve replacement.

Authors:  Creighton W Don; Michael S Kim; Edward D Verrier; Gabriel S Aldea; Larry S Dean; Mark Reisman; Nahush A Mokadam
Journal:  J Invasive Cardiol       Date:  2014-06       Impact factor: 2.022

6.  Predictive Model for Thrombus Formation After Transcatheter Valve Replacement.

Authors:  Hoda Hatoum; Shelly Singh-Gryzbon; Fateme Esmailie; Philipp Ruile; Franz-Josef Neumann; Philipp Blanke; Vinod H Thourani; Ajit P Yoganathan; Lakshmi Prasad Dasi
Journal:  Cardiovasc Eng Technol       Date:  2021-12-02       Impact factor: 2.495

Review 7.  Mechanisms and management of TAVR-related complications.

Authors:  Amir-Ali Fassa; Dominique Himbert; Alec Vahanian
Journal:  Nat Rev Cardiol       Date:  2013-10-08       Impact factor: 32.419

8.  Distal embolization of Edwards SAPIEN prosthesis during transcatheter aortic valve implantation.

Authors:  F Cuttone; C Ivascau; G Grollier; M Massetti
Journal:  G Chir       Date:  2013 Sep-Oct

9.  Mid-term follow-up after suture-less aortic heart valve implantation.

Authors:  Grzegorz Filip; Radoslaw Litwinowicz; Boguslaw Kapelak; Jacek Piatek; Magdalena Bartus; Janusz Konstanty-Kalandyk; Maciej Brzezinski; Krzysztof Bartus
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

10.  How to manage left ventricular embolization of the transcatheter valve.

Authors:  Júlia Čanádyová; Aleš Mokráček; Ladislav Pešl; Vojtěch Kurfirst
Journal:  Kardiochir Torakochirurgia Pol       Date:  2015-03-31
View more