Literature DB >> 21343520

Interobserver variability of ultrasound elastography: how it affects the diagnosis of breast lesions.

Jung Hyun Yoon1, Myung Hyun Kim, Eun-Kyung Kim, Hee Jung Moon, Jin Young Kwak, Min Jung Kim.   

Abstract

OBJECTIVE: The purpose of this article is to evaluate the interobserver variability of elastography on real-time ultrasound and how it influences the agreement of final assessment on ultrasound. SUBJECTS AND METHODS: From April to May 2009, 65 breast lesions of 53 patients (mean age, 42.6 years; range, 18-72 years) who underwent ultrasound-guided core biopsy were included in this study. Ultrasound and elastography images of the lesion subjected to biopsy were obtained and prospectively analyzed by three radiologists with individual real-time image scanning prior to biopsy. Each radiologist recorded final ultrasound BI-RADS assessments using ultrasound and combined ultrasound and elastography and the fat-to-lesion ratio and elasticity score. The histopathologic results obtained from ultrasound-guided core biopsy or excision were used as the reference standard. Diagnostic performances and interobserver agreement were analyzed.
RESULTS: Of the 65 lesions, 43 (66.2%) were benign, and 22 (33.8%) were malignant. Specificity (20.2-33.3%), positive predictive value (38.7-45.1%), and accuracy (46.7-55.4%) were significantly improved in combined ultrasound and elastography (p < 0.001). Area under the curve (AUC) values for all three performers did not show significant differences in ultrasound (AUC, 0.959) and combined ultrasound and elastography (AUC, 0.957) (p = 0.92). Interobserver agreement was not improved with combined ultrasound and elastography (κ = 0.25) in comparison to ultrasound only (κ = 0.37). Interobserver agreement of real-time elastography was fair in both fat-to-lesion ratio (intraclass correlation coefficient score, 0.25) and elasticity score (κ = 0.28). Moderate agreement (κ = 0.46) was seen with static elastography.
CONCLUSION: Elastography improves the specificity, positive predictive value, and accuracy of ultrasound. However, significant interobserver variability exists, with real-time elastographic performance showing fair agreement.

Entities:  

Mesh:

Year:  2011        PMID: 21343520     DOI: 10.2214/AJR.10.4654

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  38 in total

1.  Real-time tissue elastography assessment of skin and subcutaneous tissue strains in legs with lymphedema.

Authors:  Kotaro Suehiro; Kaori Nakamura; Noriyasu Morikage; Masanori Murakami; Osamu Yamashita; Koshiro Ueda; Makoto Samura; Kimikazu Hamano
Journal:  J Med Ultrason (2001)       Date:  2014-03-04       Impact factor: 1.314

2.  Acoustic radiation force impulse elastography in differentiating renal solid masses: a preliminary experience.

Authors:  Le-Hang Guo; Bo-Ji Liu; Hui-Xiong Xu; Chang Liu; Li-Ping Sun; Yi-Feng Zhang; Jun-Mei Xu; Jian Wu; Xiao-Hong Xu
Journal:  Int J Clin Exp Pathol       Date:  2014-10-15

3.  Characterization of laser ultrasound source signals in biological tissues for imaging applications.

Authors:  Jonathan R Fincke; Charles M Wynn; Rob Haupt; Xiang Zhang; Diego Rivera; Brian Anthony
Journal:  J Biomed Opt       Date:  2018-12       Impact factor: 3.170

4.  Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography.

Authors:  Ji Hyun Youk; Hye Mi Gweon; Eun Ju Son; Jin Chung; Jeong-Ah Kim; Eun-Kyung Kim
Journal:  Eur Radiol       Date:  2012-12-02       Impact factor: 5.315

5.  Combination of elastography and tissue quantification using the acoustic radiation force impulse (ARFI) technology for differential diagnosis of breast masses.

Authors:  Mitsuhiro Tozaki; Sachiko Isobe; Masaaki Sakamoto
Journal:  Jpn J Radiol       Date:  2012-07-18       Impact factor: 2.374

6.  Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

Authors:  Eun Jung Lee; Hae Kyoung Jung; Kyung Hee Ko; Jong Tae Lee; Jung Hyun Yoon
Journal:  Eur Radiol       Date:  2013-02-20       Impact factor: 5.315

7.  Diagnostic performances of shear-wave elastography for identification of malignant breast lesions: a meta-analysis.

Authors:  Limin Chen; Jun He; Gang Liu; Kezhong Shao; Minda Zhou; Beilei Li; Xiaofei Chen
Journal:  Jpn J Radiol       Date:  2014-09-07       Impact factor: 2.374

8.  [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

Authors:  D Rjosk-Dendorfer; A Reichelt; D-A Clevert
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

9.  Modeling Uncertainty of Strain Ratio Measurements in Ultrasound Breast Strain Elastography: A Factorial Experiment.

Authors:  David Rosen; Jingfeng Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-23       Impact factor: 2.725

10.  Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

Authors:  Jung Hyun Yoon; Hae Kyoung Jung; Jong Tae Lee; Kyung Hee Ko
Journal:  Eur Radiol       Date:  2013-05-15       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.