Literature DB >> 21333291

Mechanical properties of single bovine trabeculae are unaffected by strain rate.

M E Szabó1, M Taylor, P J Thurner.   

Abstract

For a better understanding of traumatic bone fractures, knowledge of the mechanical behavior of bone at high strain rates is required. Importantly, it needs to be clarified how quasistatic mechanical testing experiments relate to real bone fracture. This merits investigating the mechanical behavior of bone with an increase in strain rate. Various studies examined how cortical and trabecular bone behave at varying strain rates, but no one has yet looked at this question using individual trabeculae. In this study, three-point bending tests were carried out on bovine single trabeculae excised from a proximal femur to test the trabecular material's strain rate sensitivity. An experimental setup was designed, capable of measuring local strains at the surface of such small specimens, using digital image correlation. Microdamage was detected using the bone whitening effect. Samples were tested through two orders of magnitude, at strain rates varying between 0.01 and 3.39 s(-1). No linear relationship was observed between the strain rate and the Young's modulus (1.13-16.46 GPa), the amount of microdamage, the maximum tensile strain at failure (14.22-61.65%) and at microdamage initiation (1.95-12.29%). The results obtained in this study conflict with previous studies reporting various trends for macroscopic cortical and trabecular bone samples with an increase in strain rate. This discrepancy might be explained by the bone type, the small sample geometry, the limited range of strain rates tested here, the type of loading and the method of microdamage detection. Based on the results of this study, the strain rate can be ignored when modeling trabecular bone.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21333291      PMCID: PMC3088861          DOI: 10.1016/j.jbiomech.2010.12.008

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  17 in total

1.  The effects of strain rate, reconstruction and mineral content on some mechanical properties of bovine bone.

Authors:  J D Currey
Journal:  J Biomech       Date:  1975-01       Impact factor: 2.712

2.  Microtensile measurements of single trabeculae stiffness in human femur.

Authors:  Fabiano Bini; Andrea Marinozzi; Franco Marinozzi; Federico Patanè
Journal:  J Biomech       Date:  2002-11       Impact factor: 2.712

3.  Comparison of compact bone failure under two different loading rates: experimental and modelling approaches.

Authors:  M Pithioux; D Subit; P Chabrand
Journal:  Med Eng Phys       Date:  2004-10       Impact factor: 2.242

4.  Visualization of a phantom post-yield deformation process in cortical bone.

Authors:  Xuanhao Sun; Ji Hoon Jeon; John Blendell; Ozan Akkus
Journal:  J Biomech       Date:  2010-04-10       Impact factor: 2.712

5.  Tensile impact properties of human compact bone.

Authors:  S Saha; W C Hayes
Journal:  J Biomech       Date:  1976       Impact factor: 2.712

6.  Tensile testing of bone over a wide range of strain rates: effects of strain rate, microstructure and density.

Authors:  T M Wright; W C Hayes
Journal:  Med Biol Eng       Date:  1976-11

7.  Bone compressive strength: the influence of density and strain rate.

Authors:  D R Carter; W C Hayes
Journal:  Science       Date:  1976-12-10       Impact factor: 47.728

8.  Tensile testing of rodlike trabeculae excised from bovine femoral bone.

Authors:  S D Ryan; J L Williams
Journal:  J Biomech       Date:  1989       Impact factor: 2.712

9.  Experimental method for the measurement of the elastic modulus of trabecular bone tissue.

Authors:  P L Mente; J L Lewis
Journal:  J Orthop Res       Date:  1989       Impact factor: 3.494

10.  Dynamic response of bone and muscle tissue.

Authors:  J H McElhaney
Journal:  J Appl Physiol       Date:  1966-07       Impact factor: 3.531

View more
  2 in total

1.  Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model.

Authors:  Florian Kuhn; Rasmus Johannes Clausing; Alexander Stiller; Carlos Alfonso Fonseca Ulloa; Christian Foelsch; Markus Rickert; Alexander Jahnke
Journal:  J Orthop       Date:  2022-07-11

2.  A two-layer elasto-visco-plastic rheological model for the material parameter identification of bone tissue.

Authors:  Andreas G Reisinger; Martin Frank; Philipp J Thurner; Dieter H Pahr
Journal:  Biomech Model Mechanobiol       Date:  2020-05-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.