Literature DB >> 12413971

Microtensile measurements of single trabeculae stiffness in human femur.

Fabiano Bini1, Andrea Marinozzi, Franco Marinozzi, Federico Patanè.   

Abstract

In this paper, the authors perform microtensile tests of single trabeculae excised from a human femur head. One of the main issues of this work is to establish some experimental procedures for preparing and testing the specimens. The use of a well-characterized microtensile apparatus allows for a low intraspecimen dispersion of the measured stiffness. Tensile/compressive tests were chosen because they appear less sensitive to errors in the cross-sectional area measurements with respect to bending tests. By these considerations, some tensile/compressive tests of plate-like trabecular specimens have been carried out. Typical stiffness values are 74.2+/-0.7Nmm(-1) for tensile tests, and 58.9+/-0.6Nmm(-1) for compressive test. Another compressive test performed on a shorter specimen yielded a stiffness value of 148.3+/-5.3Nmm(-1). The maximum applied load was about 0.5N. Rough measurements of specimens sizes yielded a Young's modulus value ranging from 1.41 to 1.89GPa.

Entities:  

Mesh:

Year:  2002        PMID: 12413971     DOI: 10.1016/s0021-9290(02)00182-3

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  14 in total

1.  Multi-scale modelling of elastic moduli of trabecular bone.

Authors:  Elham Hamed; Iwona Jasiuk; Andrew Yoo; Yikhan Lee; Tadeusz Liszka
Journal:  J R Soc Interface       Date:  2012-01-25       Impact factor: 4.118

2.  Trabecular microfracture and the influence of pyridinium and non-enzymatic glycation-mediated collagen cross-links.

Authors:  Christopher J Hernandez; Simon Y Tang; Bethany M Baumbach; Paul B Hwu; A Nico Sakkee; Frits van der Ham; Jeroen DeGroot; Ruud A Bank; Tony M Keaveny
Journal:  Bone       Date:  2005-09-02       Impact factor: 4.398

3.  Mechanical properties of single bovine trabeculae are unaffected by strain rate.

Authors:  M E Szabó; M Taylor; P J Thurner
Journal:  J Biomech       Date:  2011-02-17       Impact factor: 2.712

4.  Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model.

Authors:  Florian Kuhn; Rasmus Johannes Clausing; Alexander Stiller; Carlos Alfonso Fonseca Ulloa; Christian Foelsch; Markus Rickert; Alexander Jahnke
Journal:  J Orthop       Date:  2022-07-11

5.  Model-Independent 3D Descriptors of Vertebral Cancellous Bone Architecture.

Authors:  Ian H Parkinson; Danielle Forbes; Peter Sutton-Smith; Nicola L Fazzalari
Journal:  J Osteoporos       Date:  2009-12-31

6.  Transient peak-strain matching partially recovers the age-impaired mechanoadaptive cortical bone response.

Authors:  Behzad Javaheri; Alessandra Carriero; Maria Wood; Roberto De Souza; Peter D Lee; Sandra Shefelbine; Andrew A Pitsillides
Journal:  Sci Rep       Date:  2018-04-27       Impact factor: 4.379

7.  A 3D Model of the Effect of Tortuosity and Constrictivity on the Diffusion in Mineralized Collagen Fibril.

Authors:  Fabiano Bini; Andrada Pica; Andrea Marinozzi; Franco Marinozzi
Journal:  Sci Rep       Date:  2019-02-25       Impact factor: 4.379

8.  Effects of Osteoporosis on Bone Morphometry and Material Properties of Individual Human Trabeculae in the Femoral Head.

Authors:  Martin Frank; Andreas G Reisinger; Dieter H Pahr; Philipp J Thurner
Journal:  JBMR Plus       Date:  2021-05-04

9.  Experimental study of diffusion coefficients of water through the collagen: apatite porosity in human trabecular bone tissue.

Authors:  Franco Marinozzi; Fabiano Bini; Alessandro Quintino; Massimo Corcione; Andrea Marinozzi
Journal:  Biomed Res Int       Date:  2014-05-21       Impact factor: 3.411

10.  Water uptake and swelling in single trabeculæ from human femur head.

Authors:  Franco Marinozzi; Fabiano Bini; Andrea Marinozzi
Journal:  Biomatter       Date:  2014-02-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.