Literature DB >> 21330564

Renal artery stenosis evaluation in chronic kidney disease patients: nonenhanced time-spatial labeling inversion-pulse three-dimensional MR angiography with regulated breathing versus DSA.

Isabelle Parienty1, Guy Rostoker, Francis Jouniaux, Michel Piotin, Faiza Admiraal-Behloul, Mitsue Miyazaki.   

Abstract

PURPOSE: To evaluate the diagnostic performance of nonenhanced magnetic resonance (MR) angiographic flow-in technique with three-dimensional balanced steady-state free precession (SSFP) (flow-in balanced SSFP), compared with digital subtraction angiography (DSA) as reference standard, for assessment of renal artery stenosis (RAS) in chronic kidney disease (CKD) patients.
MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this prospective HIPAA-compliant study. Twenty-three patients, 13 men (mean age, 67.6 years ± 8.1 [standard deviation]; age range, 58-86 years) and 10 women (mean age 73.1 years ± 12.4; age range, 49-89 years), were evaluated with flow-in balanced SSFP and DSA. Coronal and axial flow-in balanced SSFP images were obtained with 1.5-T system, with regulated breathing (recorded voice instruction). The quality of flow-in balanced SSFP images was visually evaluated; the degree of stenosis was compared between flow-in balanced SSFP source images and DSA images by using the Wilcoxon signed-rank test. Correlation between images from both modalities was calculated as the Spearman rank-order correlation coefficient; bias was examined with Bland-Altman plots.
RESULTS: Diagnostic images were obtained in all patients. Flow-in balanced SSFP image quality was good in 87% (20 of 23) and moderate in 13% (three of 23) of patients. Forty-five renal arteries were included in the statistical analysis. Of 36 stenoses detected with flow-in balanced SSFP, 28 were relevant (degree of stenosis, ≥ 50%). The stenosis measurements of flow-in balanced SSFP were highly correlated (ρ = 0.91, P < .001) with those of DSA. The Bland-Altman plot showed a slight overestimation of the degree of stenosis (mean bias, 2.33% ± 11.95). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of flow-in balanced SSFP relative to DSA for the diagnosis of a stenosis of 50% or greater were 93% (26 of 28), 88% (15 of 17), 93% (26 of 28), 88% (15 of 17), and 91% (41 of 45), respectively.
CONCLUSION: Flow-in balanced SSFP with regulated breathing is an appropriate nonenhanced MR angiographic technique for RAS assessment in CKD patients. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101422/-/DC1. RSNA, 2011

Entities:  

Mesh:

Year:  2011        PMID: 21330564     DOI: 10.1148/radiol.11101422

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Visualization of cerebrospinal fluid flow in syringomyelia through noninvasive magnetic resonance imaging with a time-spatial labeling inversion pulse (Time-SLIP).

Authors:  Kazuhiro Takeuchi; Atsushi Ono; Yusuke Hashiguchi; Haruo Misawa; Tomohiro Takahata; Arubi Teramoto; Shinnosuke Nakahara
Journal:  J Spinal Cord Med       Date:  2016-02-11       Impact factor: 1.985

Review 2.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

3.  Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

Authors:  Sung Yoon Park; Chan Kyo Kim; EunJu Kim; Byung Kwan Park
Journal:  Eur Radiol       Date:  2014-09-13       Impact factor: 5.315

4.  Non-contrast MR angiography versus contrast enhanced MR angiography for detection of renal artery stenosis: a comparative analysis in 400 renal arteries.

Authors:  Hira Lal; Rani Kunti Randhir Singh; Priyank Yadav; Ankusha Yadav; Dharmendra Bhadauria; Anuradha Singh
Journal:  Abdom Radiol (NY)       Date:  2020-11-02

5.  Hemodynamic analysis of renal artery stenosis using computational fluid dynamics technology based on unenhanced steady-state free precession magnetic resonance angiography: preliminary results.

Authors:  Weisheng Zhang; Yi Qian; Jiang Lin; Peng Lv; Kaavya Karunanithi; Mengsu Zeng
Journal:  Int J Cardiovasc Imaging       Date:  2013-12-07       Impact factor: 2.357

6.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

7.  Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

Authors:  Iliyana P Atanasova; Ruth P Lim; Hersh Chandarana; Pippa Storey; Mary T Bruno; Daniel Kim; Vivian S Lee
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

8.  Renal artery assessment with non-enhanced MR angiography versus digital subtraction angiography: comparison between 1.5 and 3.0 T.

Authors:  Xiaoxia Guo; Ying Gong; Zhiyuan Wu; Fuhua Yan; Xiaoyi Ding; Xueqin Xu
Journal:  Eur Radiol       Date:  2019-12-03       Impact factor: 5.315

9.  Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries.

Authors:  Huan Tan; Ioannis Koktzoglou; Christopher Glielmi; Mauricio Galizia; Robert R Edelman
Journal:  J Cardiovasc Magn Reson       Date:  2012-05-19       Impact factor: 5.364

10.  Magnetic resonance imaging with gradient sound respiration guide.

Authors:  Naoharu Kobayashi
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.