Literature DB >> 21330084

State of the art low-dose CT angiography of the body.

Hatem Alkadhi1, Sebastian T Schindera.   

Abstract

This review summarizes current evidence based on pertinent literature on low-dose computed tomography angiography (CTA) of the body. Various strategies for optimizing CTA protocols with the aim to lower the radiation dose while maintaining the diagnostic accuracy of the examination are summarized. To date, various publications have demonstrated that CTA of the body can be performed at a low radiation dose while providing high quality information. Nevertheless, a number of questions still need to be answered, including the optimal combination of tube voltage and tube current settings, as well as the appropriate protocol parameters in relation to the body physiognomy and the specific body region imaged.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21330084     DOI: 10.1016/j.ejrad.2010.12.099

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  11 in total

1.  Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study.

Authors:  D Ippolito; C Talei Franzesi; D Fior; P A Bonaffini; O Minutolo; S Sironi
Journal:  Br J Radiol       Date:  2015-03-18       Impact factor: 3.039

2.  Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.

Authors:  Woong Kyu Han; Joon Chae Na; Sung Yoon Park
Journal:  Eur Radiol       Date:  2019-08-30       Impact factor: 5.315

3.  Iterative model reconstruction (IMR) algorithm for reduced radiation dose renal artery CT angiography with different tube voltage protocols.

Authors:  Le Qin; ZePeng Ma; FuHua Yan; WenJie Yang
Journal:  Radiol Med       Date:  2017-10-20       Impact factor: 3.469

4.  Automatic spectral imaging protocol and iterative reconstruction for radiation dose reduction in typical hepatic hemangioma computed tomography with reduced iodine load: a preliminary study.

Authors:  Wei Li; Aiyin Li; Bin Wang; Xiuyuan Niu; Xin Cao; Xinyi Wang; Hao Shi
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

5.  Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential.

Authors:  Anna Winklehner; Christoph Karlo; Gilbert Puippe; Bernhard Schmidt; Thomas Flohr; Robert Goetti; Thomas Pfammatter; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2011-08-06       Impact factor: 5.315

6.  Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential.

Authors:  Ralph Gnannt; Anna Winklehner; Daniel Eberli; Alexander Knuth; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2012-05-02       Impact factor: 5.315

7.  Insights into imaging of aortitis.

Authors:  Diana E Litmanovich; Afra Yıldırım; Alexander A Bankier
Journal:  Insights Imaging       Date:  2012-09-20

8.  Impact of sinogram affirmed iterative reconstruction (SAFIRE) algorithm on image quality with 70 kVp-tube-voltage dual-source CT angiography in children with congenital heart disease.

Authors:  Pei Nie; Haiou Li; Yanhua Duan; Ximing Wang; Xiaopeng Ji; Zhaoping Cheng; Anbiao Wang; Jiuhong Chen
Journal:  PLoS One       Date:  2014-03-10       Impact factor: 3.240

9.  Abdominal aortic intimal flap motion characterization in acute aortic dissection: assessed with retrospective ECG-gated thoracoabdominal aorta dual-source CT angiography.

Authors:  Shifeng Yang; Xia Li; Baoting Chao; Lebin Wu; Zhaoping Cheng; Yanhua Duan; Dawei Wu; Yiqiang Zhan; Jiuhong Chen; Bo Liu; Xiaopeng Ji; Pei Nie; Ximing Wang
Journal:  PLoS One       Date:  2014-02-04       Impact factor: 3.240

10.  Diagnostic value of iterative reconstruction algorithm in low kV CT angiography (CTA) with low contrast medium volume for transcatheter aortic valve implantation (TAVI) planning: image quality and radiation dose exposure.

Authors:  Cammillo R Talei Franzesi; Davide Ippolito; Luca Riva; Davide Fior; Cecilia Cangiotti; Sandro Sironi
Journal:  Br J Radiol       Date:  2018-08-13       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.