INTRODUCTION: Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The purpose of the present study was to investigate whether the technique provides stability to match that of conventional (fixed-angle) angle-stable constructs. MATERIAL AND METHODS: In seven pairs of human cadaver radii, an Arbeitsgemeinschaft für Osteosynthese (AO) 23 C2.1 intra-articular fracture was created. One radius of each pair received a juxta-articular 2.4-mm locking compression plate (LCP) Volar Distal Radius Plate, whilst the contralateral one received a 2.4-mm Variable Angle Locking Compression Plate (LCP) Two-Column Volar Distal Radius Plate (both plates: Synthes, Oberdorf, Switzerland). Parameters tested were construct stiffness (static axial loading with 150 N), range of motion and secondary loss of reduction (dynamic 150 N axial loading over 5000 cycles). Stiffness and range of motion were measured both pre- and post-cycling. RESULTS: The polyaxial constructs were significantly stiffer, both before and after cyclic testing. However, the two-column plates showed a significant loss of stiffness during cyclic testing. The range of motion was significantly greater, both initially and at the end of cyclic testing, in the fixed-angle constructs. The conventional constructs had significantly greater secondary loss of reduction. CONCLUSION: The polyaxial two-column plate tested in this study provides a biomechanically sound construct for the management of intra-articular fractures of the distal radius. Crown
INTRODUCTION: Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The purpose of the present study was to investigate whether the technique provides stability to match that of conventional (fixed-angle) angle-stable constructs. MATERIAL AND METHODS: In seven pairs of human cadaver radii, an Arbeitsgemeinschaft für Osteosynthese (AO) 23 C2.1 intra-articular fracture was created. One radius of each pair received a juxta-articular 2.4-mm locking compression plate (LCP) Volar Distal Radius Plate, whilst the contralateral one received a 2.4-mm Variable Angle Locking Compression Plate (LCP) Two-Column Volar Distal Radius Plate (both plates: Synthes, Oberdorf, Switzerland). Parameters tested were construct stiffness (static axial loading with 150 N), range of motion and secondary loss of reduction (dynamic 150 N axial loading over 5000 cycles). Stiffness and range of motion were measured both pre- and post-cycling. RESULTS: The polyaxial constructs were significantly stiffer, both before and after cyclic testing. However, the two-column plates showed a significant loss of stiffness during cyclic testing. The range of motion was significantly greater, both initially and at the end of cyclic testing, in the fixed-angle constructs. The conventional constructs had significantly greater secondary loss of reduction. CONCLUSION: The polyaxial two-column plate tested in this study provides a biomechanically sound construct for the management of intra-articular fractures of the distal radius. Crown
Authors: Christina Salas; Justin A Brantley; James Clark; Mahmoud Reda Taha; Orrin B Myers; Deana Mercer Journal: J Hand Surg Am Date: 2018-02-06 Impact factor: 2.230
Authors: Sebastian F Baumbach; Alexander Synek; Hannes Traxler; Wolf Mutschler; Dieter Pahr; Yan Chevalier Journal: J Orthop Surg Res Date: 2015-09-08 Impact factor: 2.359
Authors: Mariya Hadzhinikolova; Ivan Zderic; Daniel Ciric; Jan P Barcik; Dian Enchev; Asen Baltov; Lyubomir Rusimov; Peter Varga; Karl Stoffel; Geoff Richards; Boyko Gueorguiev; Mihail Rashkov Journal: BMC Musculoskelet Disord Date: 2022-01-05 Impact factor: 2.362
Authors: Sebastian Felix Baumbach; Enrico Dall'Ara; Patrick Weninger; Anna Antoni; Hannes Traxler; Martin Dörr; Philippe K Zysset Journal: BMC Musculoskelet Disord Date: 2012-12-18 Impact factor: 2.362