Literature DB >> 21325362

The use of central venous catheters for intravenous contrast injection for CT examinations.

A A O Plumb1, G Murphy.   

Abstract

The use of intravenous (i.v.) contrast media in CT examinations is often of great value in improving diagnostic accuracy. The preferable route of administration is via a peripheral i.v. cannula, with powered injectors allowing reliable delivery of rapid flow rates. However, many patients with a pre-existing central venous access device may have difficult peripheral access and there is a temptation to use the central device for delivery of contrast media. This review summarises the available evidence for the safe and effective use of these devices to assist the radiologist in balancing the relative risks and benefits of their use for contrast medium injection.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21325362      PMCID: PMC3473873          DOI: 10.1259/bjr/26062221

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  17 in total

1.  Central line pump infusion and large volume mediastinal contrast extravasation in CT.

Authors:  P O'Sullivan; M Brown; B Hartnett; J R Mayo
Journal:  Br J Radiol       Date:  2006-08       Impact factor: 3.039

2.  Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation.

Authors:  B R Herts; M A Cohen; B McInroy; W J Davros; R C Zepp; D M Einstein
Journal:  Radiology       Date:  1996-09       Impact factor: 11.105

3.  In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media.

Authors:  L Ruess; D I Bulas; O Rivera; B M Markle
Journal:  Radiology       Date:  1997-06       Impact factor: 11.105

4.  Power injection of contrast media using central venous catheters: feasibility, safety, and efficacy.

Authors:  B R Herts; C M O'Malley; S L Wirth; M L Lieber; B Pohlman
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

5.  Impending catheter perforation of superior vena cava: radiographic recognition.

Authors:  I M Tocino; A Watanabe
Journal:  AJR Am J Roentgenol       Date:  1986-03       Impact factor: 3.959

6.  Fallibility of persistent blood return for confirmation of intravascular catheter placement in patients with hemorrhagic thoracic effusions.

Authors:  M H Kollef
Journal:  Chest       Date:  1994-12       Impact factor: 9.410

7.  Safe use of power injectors with central and peripheral venous access devices for pediatric CT.

Authors:  S C Kaste; C W Young
Journal:  Pediatr Radiol       Date:  1996

8.  Hypersensitivity reactions to blood components: document issued by the allergy committee of the French medicines and healthcare products regulatory agency.

Authors:  P M Mertes; A Bazin; F Alla; J Bienvenu; C Caldani; B Lamy; D Laroche; M F Leconte des Floris; J-Y Py; D Rebibo; B Willaert; P Demoly
Journal:  J Investig Allergol Clin Immunol       Date:  2011       Impact factor: 4.333

9.  Safety and feasibility of using a central venous catheter for rapid contrast injection rates.

Authors:  Pina C Sanelli; Monica Deshmukh; Igor Ougorets; Rachael Caiati; Linda A Heier
Journal:  AJR Am J Roentgenol       Date:  2004-12       Impact factor: 3.959

10.  Power injection of contrast media via peripherally inserted central catheters for CT.

Authors:  Douglas Coyle; Daniel Bloomgarden; Robert Beres; Shirish Patel; Shekhar Sane; Emil Hurst
Journal:  J Vasc Interv Radiol       Date:  2004-08       Impact factor: 3.464

View more
  6 in total

Review 1.  A narrative review of long-term central venous access devices for the intensivist.

Authors:  David Moir; Andrew Bodenham
Journal:  J Intensive Care Soc       Date:  2017-12-12

2.  Pressure injectors for radiologists: A review and what is new.

Authors:  Inna K Indrajit; Rajeev Sivasankar; John D'Souza; Rochan Pant; Raj S Negi; Samresh Sahu; Pi Hashim
Journal:  Indian J Radiol Imaging       Date:  2015 Jan-Mar

Review 3.  Contrast opacification on thoracic CT angiography: challenges and solutions.

Authors:  Abhishek Chaturvedi; Daniel Oppenheimer; Prabhakar Rajiah; Katherine A Kaproth-Joslin; Apeksha Chaturvedi
Journal:  Insights Imaging       Date:  2016-11-17

Review 4.  Systematic review of the safety and efficacy of contrast injection via venous catheters for contrast-enhanced computed tomography.

Authors:  S B Buijs; M W Barentsz; M L J Smits; J W C Gratama; P E Spronk
Journal:  Eur J Radiol Open       Date:  2017-09-29

5.  Intravenous contrast medium extravasation: systematic review and updated ESUR Contrast Media Safety Committee Guidelines.

Authors:  Giles Roditi; Nadir Khan; Aart J van der Molen; Marie-France Bellin; Michele Bertolotto; Torkel Brismar; Jean-Michel Correas; Ilona A Dekkers; Remy W F Geenen; Gertraud Heinz-Peer; Andreas H Mahnken; Carlo C Quattrocchi; Alexander Radbruch; Peter Reimer; Laura Romanini; Fulvio Stacul; Henrik S Thomsen; Olivier Clément
Journal:  Eur Radiol       Date:  2022-02-17       Impact factor: 7.034

6.  Assessment of radiopharmaceutical retention for vascular access ports using positron emission tomography imaging.

Authors:  Michael S Gossman; Huaiyu Zheng; John G Evans; Junling Li; Chin K Ng
Journal:  J Appl Clin Med Phys       Date:  2017-10-05       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.