Literature DB >> 21321251

Radiation dose to technologists per nuclear medicine examination and estimation of annual dose.

Tuncay Bayram1, A Hakan Yilmaz, Mustafa Demir, Bircan Sonmez.   

Abstract

UNLABELLED: Conventional diagnostic nuclear medicine applications have been continuously increasing in most nuclear medicine departments in Turkey, but to our knowledge no one has studied the doses to technologists who perform nuclear medicine procedures. Most nuclear medicine laboratories do not have separate control rooms for technologists, who are quite close to the patient during data acquisition. Technologists must therefore stay behind lead shields while performing their task if they are to reduce the radiation dose received. The aim of this study was to determine external radiation doses to technologists during nuclear medicine procedures with and without a lead shield. Another aim was to investigate the occupational annual external radiation doses to Turkish technologists.
METHODS: This study used a Geiger-Müller detector to measure dose rates to technologists at various distances from patients (0.25, 0.50, 1, and 2 m and behind a lead shield) and determined the average time spent by technologists at these distances. Deep-dose equivalents to technologists were obtained. The following conventional nuclear medicine procedures were considered: thyroid scintigraphy performed using (99m)Tc pertechnetate, whole-body bone scanning performed using (99m)Tc-methylene diphosphonate, myocardial perfusion scanning performed using (99m)Tc-methoxyisobutyl isonitrile, and (201)Tl (thallous chloride) and renal scanning performed using (99m)Tc-dimercaptosuccinic acid.
RESULTS: The measured deep-dose equivalent to technologists per procedure was within the range of 0.13 ± 0.05 to 0.43 ± 0.17 μSv using a lead shield and 0.21 ± 0.07 to 1.01 ± 0.46 μSv without a lead shield. Also, the annual individual dose to a technologist performing only a particular scintigraphic procedure throughout a year was estimated.
CONCLUSION: For a total of 95 clinical cases (71 patients), effective external radiation doses to technologists were found to be within the permissible levels. This study showed that a 2-mm lead shield markedly reduced the external dose to technologists. The doses to technologists varied significantly for different diagnostic applications. Consequently, the estimated annual dose to a technologist performing only a particular scintigraphic procedure is very different from one type of procedure to another. The results of this study should help in determining the rotation time of technologists in different procedures and differences in their individual techniques.

Entities:  

Mesh:

Year:  2011        PMID: 21321251     DOI: 10.2967/jnmt.110.080358

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  4 in total

1.  Time-related study on external exposure dose of 2-deoxy-2-[F-18]fluoro-D-glucose PET for workers' safety.

Authors:  Yasuyuki Takahashi; Shota Hosokawa; Takakiyo Tsujiguchi; Satoru Monzen; Takao Kanzaki; Koji Shirakawa; Ayaka Nemoto; Hayato Ishimura; Noboru Oriuchi
Journal:  Radiol Phys Technol       Date:  2019-12-12

2.  Importance of bladder radioactivity for radiation safety in nuclear medicine.

Authors:  Salih Sinan Gültekin; Turan Sahmaran
Journal:  Mol Imaging Radionucl Ther       Date:  2013-12-10

3.  Application of a tungsten apron for occupational radiation exposure in nursing care of children with neuroblastoma during 131I-meta-iodo-benzyl-guanidine therapy.

Authors:  Yuka Taniguchi; Hiroshi Wakabayashi; Hiroto Yoneyama; Zhuoqing Chen; Kei Morino; Akiko Otosaki; Masako Yamada; Anri Inaki; Daiki Kayano; Seigo Kinuya
Journal:  Sci Rep       Date:  2022-01-07       Impact factor: 4.379

4.  Occupational exposure and radiobiological risk from thyroid radioiodine therapy in Saudi Arabia.

Authors:  H I Al-Mohammed; A Sulieman; Fareed H Mayhoub; Hassan Salah; Celestino Lagarde; M Alkhorayef; Ali Aldhebaib; C Kappas; D A Bradley
Journal:  Sci Rep       Date:  2021-07-15       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.