Literature DB >> 21317907

Implantable magnetic relaxation sensors measure cumulative exposure to cardiac biomarkers.

Yibo Ling1, Terrence Pong, Christophoros C Vassiliou, Paul L Huang, Michael J Cima.   

Abstract

Molecular biomarkers can be used as objective indicators of pathologic processes. Although their levels often change over time, their measurement is often constrained to a single time point. Cumulative biomarker exposure would provide a fundamentally different kind of measurement to what is available in the clinic. Magnetic resonance relaxometry can be used to noninvasively monitor changes in the relaxation properties of antibody-coated magnetic particles when they aggregate upon exposure to a biomarker of interest. We used implantable devices containing such sensors to continuously profile changes in three clinically relevant cardiac biomarkers at physiological levels for up to 72 h. Sensor response differed between experimental and control groups in a mouse model of myocardial infarction and correlated with infarct size. Our prototype for a biomarker monitoring device also detected doxorubicin-induced cardiotoxicity and can be adapted to detect other molecular biomarkers with a sensitivity as low as the pg/ml range.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21317907     DOI: 10.1038/nbt.1780

Source DB:  PubMed          Journal:  Nat Biotechnol        ISSN: 1087-0156            Impact factor:   54.908


  25 in total

1.  High-efficiency intracellular magnetic labeling with novel superparamagnetic-Tat peptide conjugates.

Authors:  L Josephson; C H Tung; A Moore; R Weissleder
Journal:  Bioconjug Chem       Date:  1999 Mar-Apr       Impact factor: 4.774

2.  Magnetic sensors for protease assays.

Authors:  Ming Zhao; Lee Josephson; Yi Tang; Ralph Weissleder
Journal:  Angew Chem Int Ed Engl       Date:  2003-03-28       Impact factor: 15.336

3.  Crosslinked iron oxides (CLIO): a new platform for the development of targeted MR contrast agents.

Authors:  Patrick Wunderbaldinger; Lee Josephson; Ralph Weissleder
Journal:  Acad Radiol       Date:  2002-08       Impact factor: 3.173

Review 4.  Biomarkers in acute cardiac disease: the present and the future.

Authors:  Allan S Jaffe; Luciano Babuin; Fred S Apple
Journal:  J Am Coll Cardiol       Date:  2006-06-12       Impact factor: 24.094

5.  Dynamic imaging with MRI contrast agents: quantitative considerations.

Authors:  Mikhail G Shapiro; Tatjana Atanasijevic; Henryk Faas; Gil G Westmeyer; Alan Jasanoff
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

6.  Multiparameter magnetic relaxation switch assays.

Authors:  Sonia Taktak; David Sosnovik; Michael J Cima; Ralph Weissleder; Lee Josephson
Journal:  Anal Chem       Date:  2007-11-06       Impact factor: 6.986

Review 7.  Unrecognized myocardial infarction.

Authors:  S E Sheifer; T A Manolio; B J Gersh
Journal:  Ann Intern Med       Date:  2001-11-06       Impact factor: 25.391

8.  Implantable diagnostic device for cancer monitoring.

Authors:  Karen D Daniel; Grace Y Kim; Christophoros C Vassiliou; Marilyn Galindo; Alexander R Guimaraes; Ralph Weissleder; Al Charest; Robert Langer; Michael J Cima
Journal:  Biosens Bioelectron       Date:  2009-04-16       Impact factor: 10.618

Review 9.  Silent myocardial ischemia.

Authors:  David D Gutterman
Journal:  Circ J       Date:  2009-03-13       Impact factor: 2.993

Review 10.  Long-term and short-term models for studying anthracycline cardiotoxicity and protectors.

Authors:  Jacques Robert
Journal:  Cardiovasc Toxicol       Date:  2007       Impact factor: 3.231

View more
  18 in total

1.  Improving prediction of cardiovascular complications of cancer therapy: what does the future hold?

Authors:  Ana Barac
Journal:  Future Cardiol       Date:  2015-08-04

2.  Biomarkers in aggregate.

Authors:  Fred S Apple
Journal:  Nat Biotechnol       Date:  2011-03       Impact factor: 54.908

3.  Magnetic nanosensors optimized for rapid and reversible self-assembly.

Authors:  Elisenda Rodriguez; Victor S Lelyveld; Tatjana Atanasijevic; Satoshi Okada; Alan Jasanoff
Journal:  Chem Commun (Camb)       Date:  2014-02-24       Impact factor: 6.222

Review 4.  Implantable Sensors for Regenerative Medicine.

Authors:  Brett S Klosterhoff; Melissa Tsang; Didi She; Keat Ghee Ong; Mark G Allen; Nick J Willett; Robert E Guldberg
Journal:  J Biomech Eng       Date:  2017-02-01       Impact factor: 2.097

Review 5.  Magnetic nanoparticles for multi-imaging and drug delivery.

Authors:  Jae-Hyun Lee; Ji-Wook Kim; Jinwoo Cheon
Journal:  Mol Cells       Date:  2013-04-10       Impact factor: 5.034

Review 6.  High-sensitivity nanosensors for biomarker detection.

Authors:  Magdalena Swierczewska; Gang Liu; Seulki Lee; Xiaoyuan Chen
Journal:  Chem Soc Rev       Date:  2011-12-20       Impact factor: 54.564

7.  Multichannel digital heteronuclear magnetic resonance biosensor.

Authors:  Stephan Huber; Changwook Min; Christoph Staat; Juhyun Oh; Cesar M Castro; Axel Haase; Ralph Weissleder; Bernhard Gleich; Hakho Lee
Journal:  Biosens Bioelectron       Date:  2018-10-27       Impact factor: 10.618

8.  Cumulative exposure to gamma interferon-dependent chemokines CXCL9 and CXCL10 correlates with worse outcome after lung transplant.

Authors:  D C Neujahr; S D Perez; A Mohammed; O Ulukpo; E C Lawrence; F Fernandez; A Pickens; S D Force; M Song; C P Larsen; A D Kirk
Journal:  Am J Transplant       Date:  2011-12-07       Impact factor: 8.086

9.  Toward Localized In Vivo Biomarker Concentration Measurements.

Authors:  Xiaojuan Zhang; Daniel Reeves; Yipeng Shi; Barjor Gimi; Krishnamurthy V Nemani; Irina M Perreard; Seiko Toraya-Brown; Steven Fiering; John B Weaver
Journal:  IEEE Trans Magn       Date:  2015-02       Impact factor: 1.700

10.  Magnetic ligation method for quantitative detection of microRNAs.

Authors:  Monty Liong; Hyungsoon Im; Maulik D Majmudar; Aaron D Aguirre; Matthew Sebas; Hakho Lee; Ralph Weissleder
Journal:  Adv Healthc Mater       Date:  2014-02-14       Impact factor: 9.933

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.