Literature DB >> 21315207

A randomized, partially blinded, multicenter, active-controlled, dose-ranging study assessing the safety, efficacy, and pharmacodynamics of the REG1 anticoagulation system in patients with acute coronary syndromes: design and rationale of the RADAR Phase IIb trial.

Thomas J Povsic1, Mauricio G Cohen, Roxana Mehran, Christopher E Buller, Christoph Bode, Jan H Cornel, Jarosław D Kasprzak, Gilles Montalescot, Diane Joseph, William A Wargin, Christopher P Rusconi, Steven L Zelenkofske, Richard C Becker, John H Alexander.   

Abstract

Anticoagulants are the cornerstone of current acute coronary syndrome (ACS) therapy; however, anticoagulation regimens that aggressively reduce ischemic events are almost uniformly associated with more bleeding. REG1, an anticoagulation system, consists of RB006 (pegnivacogin), an RNA oligonucleotide factor IXa inhibitor, and RB007 (anivamersen), its complementary controlling agent. Phase I and IIa studies defined predictable relationships between doses of RB006, RB007, and degree of antifactor IX activity. The efficacy and safety of REG1 for the treatment of patients with ACS managed invasively and the safety of reversing RB006 with RB007 after cardiac catheterization are unknown. Randomized, partially-blinded, multicenter, active-controlled, dose-ranging study assessing the safety, efficacy, and pharmacodynamics of the REG1 anticoagulation system compared to unfractionated heparin or low molecular heparin in subjects with acute coronary syndrome (RADAR) is designed to assess both the efficacy of the anticoagulant RB006 and the safety of a range of levels of RB006 reversal with RB007. The objectives of RADAR are (1) to determine the safety of a range of levels of RB006 reversal with RB007 after catheterization, (2) to confirm whether a dose of 1 mg/kg RB006 results in near-complete inhibition of factor IXa in patients with ACS, and (3) to assess the efficacy of RB006 as an anticoagulant in patients with ACS undergoing percutaneous coronary intervention.
Copyright © 2011 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21315207     DOI: 10.1016/j.ahj.2010.10.022

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  12 in total

Review 1.  New anticoagulants in ischemic heart disease.

Authors:  Lawrence Rajan; David J Moliterno
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

Review 2.  Nucleic acid aptamers: clinical applications and promising new horizons.

Authors:  X Ni; M Castanares; A Mukherjee; S E Lupold
Journal:  Curr Med Chem       Date:  2011       Impact factor: 4.530

3.  A 1-year drug utilization evaluation of protamine in hospitalized patients to identify possible future roles of heparin and low molecular weight heparin reversal agents.

Authors:  Charles E Mahan
Journal:  J Thromb Thrombolysis       Date:  2014-04       Impact factor: 2.300

4.  Dose selection for a direct and selective factor IXa inhibitor and its complementary reversal agent: translating pharmacokinetic and pharmacodynamic properties of the REG1 system to clinical trial design.

Authors:  T J Povsic; M G Cohen; M Y Chan; S L Zelenkofske; W A Wargin; R A Harrington; J H Alexander; C P Rusconi; R C Becker
Journal:  J Thromb Thrombolysis       Date:  2011-07       Impact factor: 2.300

Review 5.  The REG1 anticoagulation system: a novel actively controlled factor IX inhibitor using RNA aptamer technology for treatment of acute coronary syndrome.

Authors:  John Paul Vavalle; Mauricio G Cohen
Journal:  Future Cardiol       Date:  2012-03-15

Review 6.  Therapeutic nucleic acids: current clinical status.

Authors:  Kannan Sridharan; Nithya Jaideep Gogtay
Journal:  Br J Clin Pharmacol       Date:  2016-06-03       Impact factor: 4.335

Review 7.  Aptamer-based targeted therapy.

Authors:  Guizhi Zhu; Xiaoyuan Chen
Journal:  Adv Drug Deliv Rev       Date:  2018-08-17       Impact factor: 15.470

Review 8.  Aptamers as therapeutics in cardiovascular diseases.

Authors:  P Wang; Y Yang; H Hong; Y Zhang; W Cai; D Fang
Journal:  Curr Med Chem       Date:  2011       Impact factor: 4.530

Review 9.  Oligonucleotide aptamers: A next-generation technology for the capture and detection of circulating tumor cells.

Authors:  David D Dickey; Paloma H Giangrande
Journal:  Methods       Date:  2015-11-26       Impact factor: 3.608

Review 10.  Translation and Clinical Development of Antithrombotic Aptamers.

Authors:  Shahid M Nimjee; Thomas J Povsic; Bruce A Sullenger; Richard C Becker
Journal:  Nucleic Acid Ther       Date:  2016-02-16       Impact factor: 5.486

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.