Literature DB >> 21311872

Fast capillary electrophoresis-time-of-flight mass spectrometry using capillaries with inner diameters ranging from 75 to 5 μm.

Marco Grundmann1, Frank-Michael Matysik.   

Abstract

Fast electrophoretic separations in fused silica capillaries (CE) coupled to time-of-flight mass spectrometry (TOF-MS) are presented. CE separations of the model analytes (epinephrine, norepinephrine, dopamine, histidine, and isoproterenol) under conditions of high electric field strengths of up to 1.25 kV cm(-1) are completed in 20 s. Coupling of CE with TOF-MS is accomplished using a coaxial sheath liquid electrospray ionization interface. The influence of parameters inherent to the interface and their effects, including suction pressure and dilution, are discussed. In addition to standard capillaries of 75 and 50 μm inner diameter (ID), separations in capillaries with IDs of 25, 15, and 5 μm have been successfully applied to this setup. The analytical performance is compared over this range of capillary dimensions, and both advantages and disadvantages are discussed.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21311872     DOI: 10.1007/s00216-011-4719-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Authors:  Mehdi Moini; Christopher M Rollman
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-07       Impact factor: 3.109

Review 2.  Small-volume analysis of cell-cell signaling molecules in the brain.

Authors:  Elena V Romanova; Jordan T Aerts; Callie A Croushore; Jonathan V Sweedler
Journal:  Neuropsychopharmacology       Date:  2013-06-10       Impact factor: 7.853

3.  Microbeam-coupled capillary electrophoresis.

Authors:  G Garty; M U Ehsan; M Buonanno; Z Yang; J V Sweedler; D J Brenner
Journal:  Radiat Prot Dosimetry       Date:  2015-04-12       Impact factor: 0.972

4.  Alternate injections coupled with flow-gated capillary electrophoresis for rapid and accurate quantitative analysis of urine samples.

Authors:  Qingfu Zhu; Qiyang Zhang; Ning Zhang; Maojun Gong
Journal:  Anal Chim Acta       Date:  2017-05-06       Impact factor: 6.558

5.  High speed capillary zone electrophoresis-mass spectrometry via an electrokinetically pumped sheath flow interface for rapid analysis of amino acids and a protein digest.

Authors:  Nicole M Schiavone; Scott A Sarver; Liangliang Sun; Roza Wojcik; Norman J Dovichi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2015-04-09       Impact factor: 3.205

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.