Literature DB >> 21311066

An analysis of inflation times during balloon-assisted aneurysm coil embolization and ischemic complications.

Alejandro M Spiotta1, Tarun Bhalla, Muhammad S Hussain, Thinesh Sivapatham, Ayush Batra, Ferdinand Hui, Peter A Rasmussen, Shaye I Moskowitz.   

Abstract

BACKGROUND AND
PURPOSE: The introduction of balloon remodeling has revolutionized the approach to coiling of wide-neck aneurysms. We studied the effects of balloon inflation during coil embolization on ischemic complications.
METHODS: A retrospective review was undertaken of the most recent 147 patients undergoing balloon remodeling for unruptured intracranial aneurysm coil embolization at a single institution (81 balloon, 66 unassisted). All underwent postprocedural MRI.
RESULTS: Among patients in the "balloon" group, the mean total inflation time was 18 minutes (range, 1-43), a mean number of inflations of 4 (range, 1-9), a mean maximum single inflation time of 7 minutes (range, 1-19), a mean reperfusion time of 2.2 minutes between inflations, and an average procedure time of 2 hours and 10 minutes. Asymptomatic diffusion-weighted imaging abnormalities were detected on postprocedural MRI in 21.5% of patients and symptomatic lesions were identified in 3.8%. Both silent and symptomatic ischemic rates were similar in the internal control group. Patients with ischemic findings were older and more likely have diabetes; no differences were found with respect to total balloon inflation time, number of inflations, maximum inflation time, or reperfusion times.
CONCLUSIONS: We found no significant relationship between balloon inflation practices and ischemic events. Older and diabetic patients were more likely to have ischemic events develop.

Entities:  

Mesh:

Year:  2011        PMID: 21311066     DOI: 10.1161/STROKEAHA.110.602276

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  14 in total

1.  Use of onyx for transarterial balloon-assisted embolization of traumatic carotid cavernous fistulas: a report of 23 cases.

Authors:  Y Yu; Q Huang; Y Xu; B Hong; W Zhao; B Deng; Y Zhang; J Liu
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-05       Impact factor: 3.825

2.  Using the pCANvas neck-bridging device in treating a wide-necked aneurysm of the basilar tip.

Authors:  Stanimir Sirakov; Adriana Panayotova; Alexander Sirakov; Marin Penkov; Krasimir Minkin; Hristo Hristov
Journal:  Neuroradiol J       Date:  2019-04-03

Review 3.  [Silent brain infarcts].

Authors:  M A Ritter; R Dittrich; E B Ringelstein
Journal:  Nervenarzt       Date:  2011-08       Impact factor: 1.214

4.  Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging.

Authors:  Tomoji Takigawa; Kensuke Suzuki; Yoshiki Sugiura; Ryotaro Suzuki; Issei Takano; Nobuyuki Shimizu; Yoshihiro Tanaka; Akio Hyodo
Journal:  Neuroradiology       Date:  2014-09-04       Impact factor: 2.804

5.  Balloon-assisted coiling of the cavernous sinus to treat direct carotid cavernous fistula. A single center experience of 13 consecutive patients.

Authors:  Alioscia De Renzis; Sergio Nappini; Arturo Consoli; Leonardo Renieri; Nicola Limbucci; Andrea Rosi; Chiara Vignoli; Giannantonio Pellicanò; Salvatore Mangiafico
Journal:  Interv Neuroradiol       Date:  2013-09-26       Impact factor: 1.610

6.  Y-configuration stent placement (crossing and kissing) for endovascular treatment of wide-neck cerebral aneurysms located at 4 different bifurcation sites.

Authors:  K-J Zhao; P-F Yang; Q-H Huang; Q Li; W-Y Zhao; J-M Liu; B Hong
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-19       Impact factor: 3.825

7.  Microembolism after Endovascular Treatment of Unruptured Cerebral Aneurysms: Reduction of its Incidence by Microcatheter Lumen Aspiration.

Authors:  Dae Yoon Kim; Jung Cheol Park; Jae Kyun Kim; Yu Sub Sung; Eun Suk Park; Jae Hyuk Kwak; Choong-Gon Choi; Deok Hee Lee
Journal:  Neurointervention       Date:  2015-09-02

8.  The Cascade device - In vitro tests to assess coil protrusion into the parent vessel.

Authors:  P Bhogal; K Wong; Hld Makalanda
Journal:  Interv Neuroradiol       Date:  2020-05-11       Impact factor: 1.610

9.  Low rates of recanalization for wide-necked aneurysms treated with stenting after balloon-assisted coiling: combination of techniques delivers stable and improved results during follow-up.

Authors:  Aglaé Velasco González; P Stracke; H Nordmeyer; M Heddier; S Saleme; C Sauerland; S Berkemeyer; B Buerke; W Heindel; R Chapot
Journal:  Neuroradiology       Date:  2018-09-05       Impact factor: 2.804

10.  A Prospective Multicenter Trial of the TransForm Occlusion Balloon Catheter: Trial Design and Results.

Authors:  M Asif Taqi; Syed A Quadri; Ajit S Puri; Brian F Fitzsimmons; Jianhua Nancy Jin; Ansaar T Rai; Curtis A Given; Javier Masso; Ciaran J Powers; Joey D English; Osama O Zaidat
Journal:  Interv Neurol       Date:  2017-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.