Literature DB >> 21310383

Higher-order aberration changes after Implantable Collamer Lens implantation for myopia.

Sun Woong Kim1, Hun Yang, Geunyoung Yoon, Yong Jun Lee, Mi-Na Kweon, Jin Kook Kim, Kyoung Yul Seo.   

Abstract

PURPOSE: To investigate the changes in higher-order aberrations (HOAs) induced by implantation of Implantable Collamer Lenses (STAAR Surgical) and to explain them in relation to the surgical incision and optical properties.
DESIGN: Prospective, observational case study.
METHODS: This study included 56 eyes undergoing Implantable Collamer Lens insertion for myopic correction. The corneal incision size was determined according to the amount of astigmatism. HOAs were measured before surgery and 3 months after surgery in 25 eyes having small superior incision (<3.2 mm) surgery and in 31 eyes with large superior incision (3.2 to 4.5 mm) surgery. Changes in spherical aberration, coma, trefoil, and total HOAs (third to sixth order) were analyzed. Laboratory measurements of aberration profiles of Implantable Collamer Lenses with different optical powers were performed to validate clinical measurements.
RESULTS: In the small-incision group, trefoil (Z(3)(-3)) and spherical aberration changed significantly (P=.004). In the large-incision group, in addition to trefoil and spherical aberration, total HOA changed significantly (mean change, 0.13 ± 0.17; P=.001). Significant correlations were observed among the incision size, the astigmatism induced, and the trefoil induced. Induced trefoil showed a predominant pattern at the orientation of the incision meridian. Optical measurement of aberrations of the Implantable Collamer Lenses confirmed the postoperative negative spherical aberration.
CONCLUSIONS: HOA changes after Implantable Collamer Lens insertion were increased trefoil and induced negative spherical aberration. These changes may be explained by the effect of the corneal incision and the negative spherical aberration in the Implantable Collamer Lens, respectively.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21310383     DOI: 10.1016/j.ajo.2010.10.031

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  9 in total

1.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

2.  Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations.

Authors:  Young Min Park; Bong Joon Choi; Jong Soo Lee
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

3.  The effects of implantable collamer lens implantation on higher order aberrations.

Authors:  Belma Kayhan; Efekan Coskunseven; Onurcan Sahin; Ioannis Pallikaris
Journal:  Int J Ophthalmol       Date:  2019-12-18       Impact factor: 1.779

4.  Spherical aberration reduction in nuclear cataracts.

Authors:  Jong-Hyuck Lee; Hun Gu Choo; Sun Woong Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-03-17       Impact factor: 3.117

5.  Visual and optical performance and quality of life after implantation of posterior chamber phakic intraocular lens.

Authors:  Rafael J Pérez-Cambrodí; Francisco J Blanes-Mompó; Santiago García-Lázaro; David P Piñero; Alejandro Cerviño; Rune Brautaset
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-05-06       Impact factor: 3.117

6.  Monochromatic higher order aberrations in highly myopic eyes with Staphyloma.

Authors:  Santiago Delgado-Tirado; Alberto López-Miguel; Yazmin Báez-Peralta; Lucía González-Buendía; Itziar Fernández; Jorge L Alió; Miguel J Maldonado; Rosa M Coco-Martín
Journal:  BMC Ophthalmol       Date:  2021-05-18       Impact factor: 2.209

7.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

8.  Ocular higher-order aberrations changes after implantable collamer lens implantation for high myopic astigmatism.

Authors:  Seyed Javad Hashemian; Hosein Farrokhi; Alireza Foroutan; Mohammad Ebrahim Jafari; Seyed Mahyar Hashemian; Sayyed Amirpooya Alemzadeh; Mahsa Sadat Hashemian
Journal:  J Curr Ophthalmol       Date:  2017-11-10

9.  Optical quality of hyperopic and myopic phakic intraocular lenses.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; David Madrid-Costa; Robert Montés-Micó
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.