Literature DB >> 21305872

CT coronary angiography for the follow-up of coronary stent.

Filippo Cademartiri1, Erica Maffie, Alessandro Palumbo, Chiara Martini, Annachiara Aldrovandi, Diego Ardissino, Valerio Brambilla, Paolo Coruzzi, Nico R Mollet, Gabriel P Krestin, Pim J de Feyter.   

Abstract

The treatment of coronary artery stenosis has progressively shifted over the past decades, from surgical (CABG) to percutaneous (PCI and stenting). The recent introduction of drug-eluting stents further reduced the occurrence of in-stent re-stenosis (ISR). However, a non-negligible number of patients need imaging/functional tests when symptoms recur. Multi-Slice CT Coronary Angiography (CT-CA) is a clinical reality for the evaluation of coronary artery stenosis, but still under evaluation in the follow-up of coronary stents. Several factors may impair proper depiction of in-stent lumen even with the most recent CT equipments. In highly selected populations CT-CA may play a clinical role even though the performance requirements both from the technical standpoint (i.e., CT scanner) and from the training (i.e., operators' experience) are still very demanding. In the meantime CT technology should improve towards higher contrast, spatial and temporal resolution in order to achieve the results that may be proper for clinical implementation.

Entities:  

Mesh:

Year:  2010        PMID: 21305872

Source DB:  PubMed          Journal:  Acta Biomed        ISSN: 0392-4203


  3 in total

1.  First in vivo head-to-head comparison of high-definition versus standard-definition stent imaging with 64-slice computed tomography.

Authors:  Tobias A Fuchs; Julia Stehli; Michael Fiechter; Svetlana Dougoud; Bert-Ram Sah; Cathérine Gebhard; Sacha Bull; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-01       Impact factor: 2.357

2.  High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning.

Authors:  Ji Won Lee; Chang Won Kim; Han Cheol Lee; Ming-Ting Wu; Lee Hwangbo; Ki Seok Choo; June Hong Kim; Ki-Nam Lee; Jin You Kim; Yeon Joo Jeong
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-29       Impact factor: 2.357

3.  Costs and clinical outcomes for non-invasive versus invasive diagnostic approaches to patients with suspected in-stent restenosis.

Authors:  James K Min; James T Hasegawa; Susanne F Machacz; Ken O'Day
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-03       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.