Literature DB >> 21300326

Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: impact upon image quality and lesion detection.

A B Rosenkrantz1, L Mannelli, D Mossa, J S Babb.   

Abstract

AIM: To compare image quality and lesion detection in the liver using magnetic resonance imaging (MRI) at 3T between T2-weighted imaging using a standard rectilinear k-space trajectory (standard T2WI) and using the BLADE technique (BLADE-T2WI), a technique that employs periodically rotated overlapping parallel lines with enhanced reconstruction for motion correction.
MATERIALS AND METHODS: Twenty-eight consecutive patients who underwent MRI examination of the liver at 3T including standard T2WI and BLADE-T2WI, both performed using multiple breath-holds, comprised the study cohort. Images were reviewed in consensus by two radiologists during separate sessions for a number of measures regarding artefacts and image quality. These two readers also assessed the two image sets for the presence of liver lesions and measured liver-to-lesion contrast. Binary logistic regression for correlated data was used to compare the sequences in terms of sensitivity and positive predictive value (PPV) for lesion detection.
RESULTS: BLADE-T2WI received significantly higher scores than did standard T2WI for in-plane respiratory motion (p=0.0195), other ghosting artefacts (p<0.0001), sharpness of the liver edge (p=0.0004), sharpness of intra-hepatic vessels (p<0.0001), flow signal suppression (p<0.0001), and overall image quality (p<0.0001). There was a non-significant trend toward improved B(1)-inhomogeneity artefact with BLADE-T2WI (p=0.0571). There was no difference in through-plane respiratory motion (p=0.6836). BLADE-T2WI demonstrated a significant improvement in PPV for lesion detection (p=0.0129) as well as in liver-to-lesion contrast (p=0.0054). There was no difference regarding lesion sensitivity (p=1.0).
CONCLUSIONS: Use of the BLADE technique for T2-weighted MRI of the liver at 3T may lead to a significant improvement in image artefacts and improved PPV for lesion detection.
Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21300326     DOI: 10.1016/j.crad.2010.10.018

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  7 in total

Review 1.  Advanced imaging techniques in pediatric body MRI.

Authors:  Jesse Courtier; Anil G Rao; Sudha A Anupindi
Journal:  Pediatr Radiol       Date:  2017-04-13

2.  Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence.

Authors:  Krishna Shanbhogue; Angela Tong; Paul Smereka; Dominik Nickel; Simon Arberet; Rebecca Anthopolos; Hersh Chandarana
Journal:  Eur Radiol       Date:  2021-05-07       Impact factor: 5.315

3.  Correlation of MRI findings to histology of acetaminophen toxicity in the mouse.

Authors:  Aliza T Brown; Xiawei Ou; Laura P James; Kedar Jambhekar; Tarun Pandey; Sandra McCullough; Shubhra Chaudhuri; Michael J Borrelli
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

4.  The Feasibility of a Fast Liver MRI Protocol for Lesion Detection of Adults at 3.0-T.

Authors:  Jing Li; Chao Ma; Yukun Chen; Caixia Fu; Xinrui Wang; Bernd Kuehn; Qingsong Yang; Jianping Lu
Journal:  Front Oncol       Date:  2021-08-04       Impact factor: 6.244

5.  Contrast-enhanced free-breathing 3D T1-weighted gradient-echo sequence for hepatobiliary MRI in patients with breath-holding difficulties.

Authors:  C S Reiner; A M Neville; H K Nazeer; S Breault; B M Dale; E M Merkle; M R Bashir
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

6.  Magnetic Resonance Imaging May Be a Valuable Radiation-Free Technique for Lung Pathologies in Patients with Primary Immunodeficiency.

Authors:  Sevket Arslan; Necdet Poyraz; Ramazan Ucar; Mihrican Yesildag; Ahmet Yesildag; Ahmet Zafer Caliskaner
Journal:  J Clin Immunol       Date:  2015-12-28       Impact factor: 8.317

7.  T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI.

Authors:  Kyung A Kang; Young Kon Kim; EunJu Kim; Woo Kyoung Jeong; Dongil Choi; Won Jae Lee; Sin-Ho Jung; Sun-Young Baek
Journal:  Korean J Radiol       Date:  2015-08-21       Impact factor: 3.500

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.