Literature DB >> 21296551

Acetabular component positioning in total hip arthroplasty: an evidence-based analysis.

Joseph T Moskal1, Susan G Capps.   

Abstract

Advocates for navigated (NAV) total hip arthroplasty (THA) emphasize the potential for improved component placement. We reviewed published literature to investigate the claim of increased precision of acetabular component placement in navigated THA compared to conventional (N-NAV) THA. Major medical and publishers' databases were searched, making no restrictions for study type, yet restricting results to English-language sources. Nine studies of varying methodological quality involving 1479 THA with a mean age of 59.10 years were included. There was no statistically significant difference in mean acetabular component abduction and anteversion angles between the NAV and N-NAV groups. There was a statistically significant difference in the incidence of acetabular component placement in the "safe zone," with NAV having significantly more "safe placements" than N-NAV, regardless of the chosen safe zone. In addition, NAV had significantly fewer dislocations than N-NAV. These outcomes demonstrate the possible patient benefit from navigation and resulting tighter control of component position.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21296551     DOI: 10.1016/j.arth.2010.11.011

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  26 in total

1.  Dislocation after total hip arthroplasty.

Authors:  A Zahar; A Rastogi; D Kendoff
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Authors:  Weifeng Ji; Nathaniel Stewart
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

3.  Higher Acetabular Anteversion in Direct Anterior Total Hip Arthroplasty: A Retrospective Case-Control Study.

Authors:  Antonia F Chen; Chi-Lung Chen; Sara Low; Wei-Ming Lin; Karthikeyan Chinnakkannu; Fabio R Orozco; Alvin C Ong; Zachary D Post
Journal:  HSS J       Date:  2016-02-19

4.  A comparison of two different navigated hip replacement techniques on leg length discrepancy.

Authors:  T N Jennison; P Craig; Edward D Davis
Journal:  J Orthop       Date:  2018-02-21

5.  Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty.

Authors:  Sarwar S Mahmood; Bariq Al-Amiry; Sebastian S Mukka; Saida Baea; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2014-11-18       Impact factor: 2.199

6.  Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty.

Authors:  Javad Fotouhi; Clayton P Alexander; Mathias Unberath; Giacomo Taylor; Sing Chun Lee; Bernhard Fuerst; Alex Johnson; Greg Osgood; Russell H Taylor; Harpal Khanuja; Mehran Armand; Nassir Navab
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

7.  A new system of computer-assisted navigation leading to reduction in operating time in uncemented total hip replacement in a matched population.

Authors:  Fouad A Chaudhry; Sanaa Z Ismail; Edward T Davis
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-29

8.  A new method for intraoperative assessment of leg length, sizing and placement of the components in total hip replacement.

Authors:  Ioannis P Stathopoulos; Nicolaos Andrianopoulos; Dimitrios Paschaloglou; Kalliopi Lampropoulou-Adamidou; Maria Spetsaki; Ioannis K Tsarouchas
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-01-02

9.  Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

Authors:  Brandon S Beamer; Jordan H Morgan; Christopher Barr; Michael J Weaver; Mark S Vrahas
Journal:  Clin Orthop Relat Res       Date:  2014-09-20       Impact factor: 4.176

10.  Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis.

Authors:  Ho-Rim Choi; David Anderson; Scott Foster; Matthew Beal; Jo Ann Lee; Christopher Barr; Henrik Malchau; Joseph McCarthy; Young-Min Kwon
Journal:  Int Orthop       Date:  2013-07-24       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.