Literature DB >> 21292929

Posterior fixation of the upper cervical spine: contemporary techniques.

Richard J Bransford1, Michael J Lee, Abilio Reis.   

Abstract

Instrumentation in the upper cervical spine has changed considerably in the past two decades. Previous stand-alone wiring techniques have been made largely obsolete with the development of occipital segmental plating, transarticular screws, and C1 lateral mass screws, as well as a myriad of C2 fixation options, including pedicle, pars, and translaminar screws. Polyaxial screws and segmental fixation are more user-friendly than stand-alone wiring and provide a stronger construct. Awareness of the risks and benefits associated with the use of modern instrumentation and thorough familiarity with the anatomy of the upper cervical spine are essential to avoid complications and optimize outcomes.

Mesh:

Year:  2011        PMID: 21292929     DOI: 10.5435/00124635-201102000-00001

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  10 in total

1.  Outcomes from 18 years of cervical spine surgery in MPS IVA: a single centre's experience.

Authors:  A Broomfield; K Zuberi; J Mercer; G Moss; N Finnegan; P Hensman; R Walker; S Bukhari; N B Wright; F Stewart; S A Jones; R Ramirez
Journal:  Childs Nerv Syst       Date:  2018-06-26       Impact factor: 1.475

2.  Lateral mass screw placement in the atlas: description of a novel surgical technique, radiographic parameters, and review of the literature.

Authors:  Bilal B Butt; Paul Gagnet; Joshua Piche; Rakesh Patel; Paul Park; Ilyas S Aleem
Journal:  J Spine Surg       Date:  2021-09

3.  Posterior stabilization of cervical spine injuries using the Roy-Camille plates: a long-term follow-up.

Authors:  Demitrios Korres; Vassilios S Nikolaou; Maria Kaseta; Demetrios Evangelopoulos; Kostas Markatos; John Lazarettos; Nicolas Efstathopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-10

4.  Atlanto-axial rotary instability (Fielding type 1): characteristic clinical and radiological findings, and treatment outcomes following alignment, fusion, and stabilization.

Authors:  Fraser C Henderson; Robert Rosenbaum; Malini Narayanan; Myles Koby; Kelly Tuchman; Peter C Rowe; Clair Francomano
Journal:  Neurosurg Rev       Date:  2020-07-04       Impact factor: 3.042

5.  Nonoperative Management of Craniocervical Ligamentous Distraction Injury: Literature Review.

Authors:  Nathan B Kaplan; Christine Molinari; Robert W Molinari
Journal:  Global Spine J       Date:  2015-12

6.  A Novel Patient-Specific Drill Guide Template for Pedicle Screw Insertion into the Subaxial Cervical Spine Utilizing Stereolithographic Modelling: An In Vitro Study.

Authors:  Rafael Cruz Bundoc; Giorgio De Guzman Delgado; Samuel Arsenio Munoz Grozman
Journal:  Asian Spine J       Date:  2017-02-17

7.  An anatomic consideration of C2 vertebrae artery groove variation for individual screw implantation in axis.

Authors:  Janhua Wang; Hong Xia; Qingshui Ying; Yang Lu; Zenghui Wu; Fzhi Ai; Xiangyang Ma
Journal:  Eur Spine J       Date:  2013-05-10       Impact factor: 3.134

Review 8.  Spinal involvement in mucopolysaccharidosis IVA (Morquio-Brailsford or Morquio A syndrome): presentation, diagnosis and management.

Authors:  Guirish A Solanki; Kenneth W Martin; Mary C Theroux; Christina Lampe; Klane K White; Renée Shediac; Christian G Lampe; Michael Beck; William G Mackenzie; Christian J Hendriksz; Paul R Harmatz
Journal:  J Inherit Metab Dis       Date:  2013-02-06       Impact factor: 4.982

Review 9.  A review of the diagnosis and treatment of atlantoaxial dislocations.

Authors:  Sun Y Yang; Anthony J Boniello; Caroline E Poorman; Andy L Chang; Shenglin Wang; Peter G Passias
Journal:  Global Spine J       Date:  2014-05-22

Review 10.  Palliative Surgery in Treating Painful Metastases of the Upper Cervical Spine: Case Report and Review of the Literature.

Authors:  Xinghuo Wu; Zhewei Ye; Feifei Pu; Songfeng Chen; Baichuan Wang; Zhicai Zhang; Cao Yang; Shuhua Yang; Zengwu Shao
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.