Literature DB >> 21292491

Metal hypersensitivity in total knee arthroplasty: revision surgery using a ceramic femoral component - a case report.

Philipp Bergschmidt1, Rainer Bader, Wolfram Mittelmeier.   

Abstract

We present a case involving the revision of a total knee arthroplasty with a metal femoral component using a ceramic implant due to metal hypersensitivity. A 58-year-old female patient underwent total knee arthroplasty (TKA) with a standard metal bicondylar knee system. She suffered from persistent pain and strong limitations in her range of motion (ROM) associated with flexion during the early postoperative period. Arthroscopic arthrolysis of the knee joint and intensive active and passive physical treatment, in combination with a cortisone regime, temporarily increased the ROM and reduced pain. No signs of low grade infection or other causes of implant failure were evident. Histology of synovial tissue revealed lymphoplasmacellular fibrinous tissue, consistent with a type IV allergic reaction. Allergometry (skin reaction) revealed type IV hypersensitivity against nickel-II-sulfate and palladium chloride. Revision surgery of the metal components was performed with a cemented ceramic femoral component (same bicondylar design) and a cemented titanium alloy tibial component. Postoperative evaluations were performed 10days, and 3 and 12months after the revision surgery. There was an increased ROM in flexion to 90° at the 12month follow-up. No swelling or effusion was observed at all clinical examinations after the revision surgery. No pain at rest and moderate walking pain were evident. The presented case demonstrates that ceramic implants are a promising solution for patients suffering from hypersensitivity to metal ions in total knee arthroplasty.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21292491     DOI: 10.1016/j.knee.2011.01.001

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  14 in total

Review 1.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

Review 2.  Metal Hypersensitivity and Total Knee Arthroplasty.

Authors:  Paul F Lachiewicz; Tyler Steven Watters; Joshua J Jacobs
Journal:  J Am Acad Orthop Surg       Date:  2016-02       Impact factor: 3.020

3.  What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty?

Authors:  Christina M Arnholt; Daniel W MacDonald; Gregg R Klein; Harold E Cates; Clare M Rimnac; Steven M Kurtz; Sevi Kocagoz; Antonia F Chen
Journal:  J Arthroplasty       Date:  2018-05-17       Impact factor: 4.757

Review 4.  No allergic reaction after TKA in a chrome-cobalt-nickel-sensitive patient: case report and review of the literature.

Authors:  Emmanuel Thienpont; Yorick Berger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-10       Impact factor: 4.342

5.  Mechanically assisted taper corrosion in modular TKA.

Authors:  Christina M Arnholt; Daniel W MacDonald; Mariya Tohfafarosh; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz; Gregg Klein; Michael A Mont; Javad Parvizi; Harold E Cates; Gwo-Chin Lee; Arthur Malkani; Mattheuw Kraay
Journal:  J Arthroplasty       Date:  2014-05-28       Impact factor: 4.757

Review 6.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

7.  [Histopathological particle algorithm. Particle identification in the synovia and the SLIM].

Authors:  V Krenn; P Thomas; M Thomsen; J P Kretzer; S Usbeck; L Scheuber; G Perino; W Rüther; R v Welser; F Hopf; M Huber
Journal:  Z Rheumatol       Date:  2014-09       Impact factor: 1.372

8.  Preliminary In Vitro Wear Assessment of Ceramic Cemented Femoral Components Coupled with Polyethylene Menisci.

Authors:  Saverio Affatato; Paolo Erani; Maurizio Fersini; Vincenzo Contaldi; Anna Rita Terrizzi; Antonio Licciulli
Journal:  Materials (Basel)       Date:  2021-04-22       Impact factor: 3.623

Review 9.  Biomaterial hypersensitivity: is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty.

Authors:  Andrew J Mitchelson; Craig J Wilson; William M Mihalko; Thomas M Grupp; Blaine T Manning; Douglas A Dennis; Stuart B Goodman; Tony H Tzeng; Sonia Vasdev; Khaled J Saleh
Journal:  Biomed Res Int       Date:  2015-03-25       Impact factor: 3.411

10.  Ceramic femoral components in total knee arthroplasty - two year follow-up results of an international prospective multi-centre study.

Authors:  Philipp Bergschmidt; Rainer Bader; Dirk Ganzer; Christian Hauzeur; Christoph Lohmann; Wolfgang Rüther; Domenico Tigani; Nicola Rani; Fernando Lopez Prats; Claudio Zorzi; Vincenzo Madonna; Stefano Rigotti; Francesco Benazzo; Stefano Marco Paolo Rossi; Guenther Kundt; Hans Rudolf Bloch; Wolfram Mittelmeier
Journal:  Open Orthop J       Date:  2012-04-20
View more