Daniel Gerrity1, Sujanie Gamage, Janie C Holady, Douglas B Mawhinney, Oscar Quiñones, Rebecca A Trenholm, Shane A Snyder.
Abstract
In an effort to validate the use of ozone for contaminant oxidation and disinfection in water reclamation, extensive pilot testing was performed with ozone/H(2)O(2) and biological activated carbon (BAC) at the Reno-Stead Water Reclamation Facility in Reno, Nevada. Three sets of samples were collected over a five-month period of continuous operation, and these samples were analyzed for a suite of trace organic contaminants (TOrCs), total estrogenicity, and several microbial surrogates, including the bacteriophage MS2, total and fecal coliforms, and Bacillus spores. Based on the high degree of microbial inactivation and contaminant destruction, this treatment train appears to be a viable alternative to the standard indirect potable reuse (IPR) configuration (i.e., membrane filtration, reverse osmosis, UV/H(2)O(2), and aquifer injection), particularly for inland applications where brine disposal is an issue. Several issues, including regrowth of coliform bacteria in the BAC process, must be addressed prior to full-scale implementation.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21288550 DOI: 10.1016/j.watres.2010.12.031
Source DB: PubMed Journal: Water Res ISSN: 0043-1354 Impact factor: 11.236