Literature DB >> 21288309

Automated alternation flicker for the detection of optic disc haemorrhages.

Zeba A Syed1, Nathan M Radcliffe, Carlos Gustavo De Moraes, Scott D Smith, Jeffrey M Liebmann, Robert Ritch.   

Abstract

PURPOSE: Optic disc haemorrhages are associated with active glaucomatous neurodegeneration and ongoing visual field loss. We sought to determine whether automated alternation flicker enhances the detection of disc haemorrhages in serial images from patients with glaucoma when compared to side-by-side photographic evaluation and single-image display.
METHODS: Serial sets of optic nerve photographs of 394 eyes from 234 patients followed for glaucoma at the authors' institutions were included in this study. Eyes with disc haemorrhages were graded for difficulty level and randomized along with nondisc haemorrhage control images into one of three presentation groups (automated alternation flicker, side-by-side or single image). Seven graders viewed all images and assessed for the presence or absence of disc haemorrhages.
RESULTS: The sensitivity of automated alternation flicker for disc haemorrhage detection (0.878) was higher than side-by-side (0.705; p = 0.002) and single photographs (0.757; p = 0.01). There was no specificity difference between pairs of presentation groups (all p ≥ 0.7).
CONCLUSION: Automated alternation flicker was a more sensitive method for disc haemorrhage detection than the current clinical standards and may have an important role in the management of glaucoma.
© 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2011        PMID: 21288309     DOI: 10.1111/j.1755-3768.2010.02094.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  6 in total

1.  Evaluation of vascular disease progression in retinopathy of prematurity using static and dynamic retinal images.

Authors:  Jane S Myung; Rony Gelman; Grant D Aaker; Nathan M Radcliffe; R V Paul Chan; Michael F Chiang
Journal:  Am J Ophthalmol       Date:  2011-10-22       Impact factor: 5.258

2.  Comparison of retinal image evaluation techniques in novice clinicians.

Authors:  Christopher M Putnam; Alex Permann; Carl J Bassi
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-22

3.  Developing new automated alternation flicker using optic disc photography for the detection of glaucoma progression.

Authors:  J Ahn; I S Yun; H G Yoo; J-J Choi; M Lee
Journal:  Eye (Lond)       Date:  2016-09-23       Impact factor: 3.775

4.  The impact of disc hemorrhage studies on our understanding of glaucoma: a systematic review 50 years after the rediscovery of disc hemorrhage.

Authors:  Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2018-11-21       Impact factor: 2.447

5.  Structural glaucomatous progression before and after occurrence of an optic disc haemorrhage.

Authors:  Esther Chung; Anna M Demetriades; Paul J Christos; Nathan M Radcliffe
Journal:  Br J Ophthalmol       Date:  2014-07-23       Impact factor: 4.638

6.  The association between retinal vein pulsation pressure and optic disc haemorrhages in glaucoma.

Authors:  Dong An; Philip House; Christopher Barry; Andrew Turpin; Allison M McKendrick; Balwantray C Chauhan; Siobhan Manners; Stuart L Graham; Dao-Yi Yu; William H Morgan
Journal:  PLoS One       Date:  2017-07-28       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.