Literature DB >> 21285488

A robotic approach to 4D real-time tumor tracking for radiotherapy.

I Buzurovic1, K Huang, Y Yu, T K Podder.   

Abstract

Respiratory and cardiac motions induce displacement and deformation of the tumor volumes in various internal organs. To accommodate this undesired movement and other errors, physicians incorporate a large margin around the tumor to delineate the planning target volume, so that the clinical target volume receives the prescribed radiation dose under any scenario. Consequently, a large volume of healthy tissue is irradiated and sometimes it is difficult to spare critical organs adjacent to the tumor. In this study we have proposed a novel approach to the 4D active tracking and dynamic delivery incorporating the tumor motion prediction technique. This method has been applied to the two commercially available robotic treatment couches. The proposed algorithm can predict the tumor position and the robotic systems are able to continuously track the tumor during radiation dose delivery. Therefore a precise dose is given to a moving target while the dose to the nearby critical organs is reduced to improve the patient treatment outcome. The efficacy of the proposed method has been investigated by extensive computer simulation. The tumor tracking method is simulated for two couches: HexaPOD robotic couch and ELEKTA Precise Table. The comparison results have been presented in this paper. In order to assess the clinical significance, dosimetric effects of the proposed method have been analyzed.

Entities:  

Mesh:

Year:  2011        PMID: 21285488     DOI: 10.1088/0031-9155/56/5/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Implementation and experimental results of 4D tumor tracking using robotic couch.

Authors:  I Buzurovic; Y Yu; M Werner-Wasik; T Biswas; P R Anne; A P Dicker; T K Podder
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

2.  Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac.

Authors:  Joseph E McNamara; Rajesh Regmi; D Michael Lovelock; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Hassan Mostafavi; Gig S Mageras
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

3.  Optimized order estimation for autoregressive models to predict respiratory motion.

Authors:  Robert Dürichen; Tobias Wissel; Achim Schweikard
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-05-21       Impact factor: 2.924

4.  Development of a four-axis moving phantom for patient-specific QA of surrogate signal-based tracking IMRT.

Authors:  Nobutaka Mukumoto; Mitsuhiro Nakamura; Masahiro Yamada; Kunio Takahashi; Mami Akimoto; Yuki Miyabe; Kenji Yokota; Shuji Kaneko; Akira Nakamura; Satoshi Itasaka; Yukinori Matsuo; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

5.  Optimization based trajectory planning for real-time 6DoF robotic patient motion compensation systems.

Authors:  Xinmin Liu; Rodney D Wiersma
Journal:  PLoS One       Date:  2019-01-11       Impact factor: 3.240

6.  The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy.

Authors:  Giovanni Fattori; Ye Zhang; David Meer; Damien Charles Weber; Antony John Lomax; Sairos Safai
Journal:  Sci Rep       Date:  2020-09-18       Impact factor: 4.379

7.  SlicerArduino: A Bridge between Medical Imaging Platform and Microcontroller.

Authors:  Paolo Zaffino; Alessio Merola; Domenico Leuzzi; Virgilio Sabatino; Carlo Cosentino; Maria Francesca Spadea
Journal:  Bioengineering (Basel)       Date:  2020-09-11

8.  Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy.

Authors:  Guangyu Wang; Zhibin Li; Guangjun Li; Guyu Dai; Qing Xiao; Long Bai; Yisong He; Yaxin Liu; Sen Bai
Journal:  Radiat Oncol       Date:  2021-01-14       Impact factor: 3.481

9.  Determining leaf trajectories for dynamic multileaf collimators with consideration of marker visibility: an algorithm study.

Authors:  Bo Zhao; Jianrong Dai
Journal:  J Radiat Res       Date:  2014-06-08       Impact factor: 2.724

10.  A respiratory compensating system: design and performance evaluation.

Authors:  Ho-Chiao Chuang; Ding-Yang Huang; Der-Chi Tien; Ren-Hong Wu; Chung-Hsien Hsu
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

  10 in total