Literature DB >> 21281951

Durability of bioprosthetic valves in the pulmonary position: long-term follow-up of 181 implants in patients with congenital heart disease.

Cheul Lee1, Chun Soo Park, Chang-Ha Lee, Jae Gun Kwak, Soo-Jin Kim, Woo-Sup Shim, Jin Young Song, Eun Young Choi, Sang Yun Lee.   

Abstract

OBJECTIVES: Durability of bioprosthetic valves in the pulmonary position is not well defined. We examined the durability of bioprosthetic valves in the pulmonary position and risk factors associated with bioprosthetic pulmonary valve failure.
METHODS: Between 1993 and 2004, 181 patients underwent pulmonary valve replacement using bioprostheses. Patients who underwent valved conduit or homograft implantation were excluded. Mean age was 14.2 ± 9.8 years and median valve size was 23 mm (range, 19-27 mm). Types of bioprosthesis used were Hancock II (n = 83), Perimount (n = 53), Freestyle (n = 23), Carpentier-Edwards porcine valve (n = 18), and others (n = 4).
RESULTS: There were 3 early and 7 late deaths. Follow-up completeness was 88.6% and mean follow-up duration was 7.3 ± 2.9 years. Forty-three patients underwent redo pulmonary valve replacement. Overall freedom from redo pulmonary valve replacement at 5 and 10 years was 93.9% ± 1.9% and 51.7% ± 8.6%, respectively. Overall freedom from both valve failure and valve dysfunction at 5 and 10 years was 92.2% ± 2.1% and 20.2% ± 6.7%, respectively. In multivariable analysis, younger age at operation, diagnosis of pulmonary atresia with ventricular septal defect, and use of stentless valve were identified as risk factors for redo pulmonary valve replacement.
CONCLUSIONS: Durability of bioprosthetic valves in the pulmonary position was suboptimal. Valve function was maintained stable until 5 years after operation. By 10 years, however, about 80% will require reoperation or manifest valve dysfunction. In our experience, the stentless valve was less durable than stented valves.
Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21281951     DOI: 10.1016/j.jtcvs.2010.12.020

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  21 in total

1.  Right ventricular outflow tract aneurysm with thrombus.

Authors:  Syed Murfad Peer; P S Seetharama Bhat; Arul Dominic Furtado; Raghavendra Chikkatur
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-09

2.  Pulmonary valve replacement long after repair of tetralogy of Fallot.

Authors:  Yuichi Shiokawa; Hiromichi Sonoda; Yoshihisa Tanoue; Takahiro Nishida; Atsuhiro Nakashima; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2012-05-08

3.  The use of thermal techniques for the characterization and selection of natural biomaterials.

Authors:  Valérie Samouillan; Florian Delaunay; Jany Dandurand; Nofel Merbahi; Jean-Pierre Gardou; Mohammed Yousfi; Alessandro Gandaglia; Michel Spina; Colette Lacabanne
Journal:  J Funct Biomater       Date:  2011-09-13

Review 4.  Late postoperative prosthetic pulmonary valve endocarditis in a 13-year-old girl with repaired tetralogy of fallot.

Authors:  Michael C O'Brien; Kamal K Pourmoghadam; William M DeCampli
Journal:  Tex Heart Inst J       Date:  2015-06-01

5.  Porcine bioprosthetic valve in the pulmonary position: mid-term results in the right ventricular outflow tract reconstruction.

Authors:  Alessandro Giamberti; Massimo Chessa; Matteo Reali; Alessandro Varrica; Halkawt Nuri; Giuseppe Isgrò; Alessandro Frigiola; Marco Ranucci
Journal:  Pediatr Cardiol       Date:  2013-02-24       Impact factor: 1.655

6.  Initial scaffold thickness affects the emergence of a geometrical and mechanical equilibrium in engineered cardiovascular tissues.

Authors:  M A J van Kelle; P J A Oomen; W J T Janssen-van den Broek; R G P Lopata; S Loerakker; C V C Bouten
Journal:  J R Soc Interface       Date:  2018-11-14       Impact factor: 4.118

Review 7.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

Review 8.  Valve-in-valve implantations: is this the new standard for degenerated bioprostheses? Review of the literature.

Authors:  Krys Milburn; Vinayak Bapat; Martyn Thomas
Journal:  Clin Res Cardiol       Date:  2014-01-21       Impact factor: 5.460

Review 9.  Postoperative residua and sequelae in adults with repaired tetralogy of Fallot.

Authors:  Munetaka Masuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-04-26

Review 10.  Pulmonic Valve Disease: Review of Pathology and Current Treatment Options.

Authors:  Mouhammad Fathallah; Richard A Krasuski
Journal:  Curr Cardiol Rep       Date:  2017-09-16       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.