Literature DB >> 21276887

The comparative stability of screw versus plate versus screw and plate coronoid fixation.

Jeffrey E Budoff1, D Nicole Meyers, Catherine G Ambrose.   

Abstract

PURPOSE: To compare the biomechanical characteristics of screw versus plate versus both screw and plate fixation for large, type 3 O'Driscoll coronoid fractures.
METHODS: Synthetic ulnas had 70% of their coronoids cut. Fixation was performed with either a cannulated screw, a plate, or both a screw and a plate. Energy to failure, force at failure, first cycle stiffness, and stiffness at failure were measured on a servohydraulic testing machine under cyclic posterior axial loading.
RESULTS: The combination of a plate and screw had significantly greater energy to failure (83 Nm), force required to cause failure (634 N), and stiffness at failure (387 N/mm) compared to either an isolated plate (38 Nm, 474 N, 237 N/mm, respectively) or a screw (10 Nm, 279 N, 149 N/mm, respectively). For energy to failure and force required to cause failure, the plate group significantly outperformed the screw group. There was no significant difference in stiffness at the time of failure between the plate and screw groups.
CONCLUSIONS: For type 3 O'Driscoll coronoid fractures or nonunions when both a screw and a plate can be placed, the combination of these 2 fixation devices appears to produce significantly greater biomechanical stability than either fixation device alone.
Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21276887     DOI: 10.1016/j.jhsa.2010.10.022

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Good outcome using anatomically pre-formed buttress plates for anteromedial facet fractures of the coronoid-a retrospective study of twenty-four patients.

Authors:  Alexander Klug; Stefan Buschbeck; Yves Gramlich; Johannes Buckup; Reinhard Hoffmann; Kay Schmidt-Horlohé
Journal:  Int Orthop       Date:  2019-06-07       Impact factor: 3.075

2.  Mechanical Evaluation of Four Internal Fixation Constructs for Scaphoid Fractures.

Authors:  Bryan G Beutel; Eitan Melamed; Richard M Hinds; Michael B Gottschalk; John T Capo
Journal:  Hand (N Y)       Date:  2016-01-14

Review 3.  Composite bone models in orthopaedic surgery research and education.

Authors:  John Elfar; Ron Martin Garcia Menorca; Jeffrey Douglas Reed; Spencer Stanbury
Journal:  J Am Acad Orthop Surg       Date:  2014-02       Impact factor: 3.020

4.  Biomechanical comparison of screw osteosyntheses and anatomical plating for coronoid shear fractures of the ulna.

Authors:  Valentin Rausch; Birger Jettkant; Sebastian Lotzien; Thomas Rosteius; Eileen Mempel; Thomas A Schildhauer; Dominik Seybold; Jan Geßmann; Matthias Königshausen
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-12       Impact factor: 3.067

  4 in total