Literature DB >> 21274976

Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload.

Antonella Meloni1, Antongiulio Luciani, Vincenzo Positano, Daniele De Marchi, Gianluca Valeri, Gennaro Restaino, Eliana Cracolici, Vincenzo Caruso, Maria Chiara Dell'amico, Brunella Favilli, Massimo Lombardi, Alessia Pepe.   

Abstract

PURPOSE: To evaluate the effectiveness of the single ROI approach for the detection of hepatic iron burden in thalassemia major (TM) patients in respect to a whole liver measurement.
MATERIALS AND METHODS: Five transverse hepatic slices were acquired by a T2* gradient-echo sequence in 101 TM patients and 20 healthy subjects. The T2* value was calculated in a single region of interest (ROI) defined in the medium-hepatic slice. Moreover, the T2* value was extracted on each of the eight ROIs defined in the functionally independent segments. The mean hepatic T2* value was calculated.
RESULTS: For patients, the mean T2* values over segments VII and VIII were significantly lower. This pattern was substantially preserved in the two groups identified considering the T2* normal cutoff. All segmental T2* values were correlated with the single ROI T2* value. After the application of a correction map based on T2* fluctuations in the healthy subjects, no significant differences were found in the segmental T2* values.
CONCLUSION: Hepatic T2* variations are low and due to artifacts and measurement variability. The single ROI approach can be adopted in the clinical arena, taking care to avoid the susceptibility artifacts, occurring mainly in segments VII and VIII.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21274976     DOI: 10.1002/jmri.22417

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  18 in total

1.  Prospective cardiac magnetic resonance imaging survey in myelodysplastic syndrome patients: insights from an Italian network.

Authors:  Alessia Pepe; Michele Rizzo; Sara Galimberti; Claudia Baratè; Esther Natalie Oliva; Francesco Arcioni; Sergio Storti; Stefania Renne; Massimo Midiri; Gennaro Restaino; Vincenzo Positano; Maurizio Mangione; Antonella Meloni
Journal:  Ann Hematol       Date:  2021-03-19       Impact factor: 3.673

Review 2.  MR imaging assessment and quantification of liver iron.

Authors:  Manuela França; João Gomes Carvalho
Journal:  Abdom Radiol (NY)       Date:  2020-11

3.  Effect of inversion recovery fat suppression on hepatic R2* quantitation in transfusional siderosis.

Authors:  Antonella Meloni; J Michael Tyszka; Alessia Pepe; John C Wood
Journal:  AJR Am J Roentgenol       Date:  2015-03       Impact factor: 3.959

4.  Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

Authors:  Ralf B Loeffler; M Beth McCarville; Anne W Wagstaff; Matthew P Smeltzer; Axel J Krafft; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand
Journal:  Pediatr Radiol       Date:  2016-10-17

5.  The use of appropriate calibration curves corrects for systematic differences in liver R2* values measured using different software packages.

Authors:  Antonella Meloni; Hugh Y Rienhoff; Amber Jones; Alessia Pepe; Massimo Lombardi; John C Wood
Journal:  Br J Haematol       Date:  2013-03-18       Impact factor: 6.998

6.  Multipeak fat-corrected complex R2* relaxometry: theory, optimization, and clinical validation.

Authors:  Diego Hernando; J Harald Kramer; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-01-28       Impact factor: 4.668

7.  Genotypic groups as risk factors for cardiac magnetic resonance abnormalities and complications in thalassemia major: a large, multicentre study.

Authors:  Laura Pistoia; Antonella Meloni; Paolo Ricchi; Aldo Filosa; Roberto Lisi; Aurelio Maggio; Rosamaria Rosso; Giuseppe Messina; Nicola Dello Iacono; Liana Cuccia; Saveria Campisi; Massimiliano Missere; Massimo Midiri; Antonino Vallone; Stefania Renne; Nicolò Schicchi; Riccardo Righi; Maurizio Mangione; Vincenzo Positano; Alessia Pepe
Journal:  Blood Transfus       Date:  2020-07-22       Impact factor: 3.443

8.  High spatial resolution and temporally resolved T2* mapping of normal human myocardium at 7.0 Tesla: an ultrahigh field magnetic resonance feasibility study.

Authors:  Fabian Hezel; Christof Thalhammer; Sonia Waiczies; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  PLoS One       Date:  2012-12-14       Impact factor: 3.240

9.  Cardiac and hepatic iron and ejection fraction in thalassemia major: multicentre prospective comparison of combined deferiprone and deferoxamine therapy against deferiprone or deferoxamine monotherapy.

Authors:  Alessia Pepe; Antonella Meloni; Giuseppe Rossi; Liana Cuccia; Giuseppe Domenico D'Ascola; Michele Santodirocco; Paolo Cianciulli; Vincenzo Caruso; Maria Antonietta Romeo; Aldo Filosa; Lorella Pitrolo; Maria Caterina Putti; Angelo Peluso; Saveria Campisi; Massimiliano Missere; Massimo Midiri; Letizia Gulino; Vincenzo Positano; Massimo Lombardi; Paolo Ricchi
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-16       Impact factor: 5.364

10.  A practical approach for a wide range of liver iron quantitation using a magnetic resonance imaging technique.

Authors:  Ping Hou; Uday R Popat; Richard J Lindsay; Edward F Jackson; Haesun Choi
Journal:  Radiol Res Pract       Date:  2012-12-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.