Literature DB >> 21267470

Evaluation of apparent non-specific protein loss due to adsorption on sample tube surfaces and/or altered immunogenicity.

Chandra K Dixit1, Sandeep K Vashist, Brian D MacCraith, Richard O'Kennedy.   

Abstract

The non-specific loss of protein analytes can have a major effect on assay results particularly where the concentrations of such analytes are extremely low and the matrix is complex. This report assesses how the protein incubated in sample tubes may be lost due to adsorption. Use of proteins, such as bovine serum albumin (BSA), may be used to pre-treat tubes to reduce such losses. However, such losses may also be associated with structural perturbations leading to changes in immunogenicity (as a result of alterations in specific epitope-related conformations). This can lead to erroneous results or lack of comparability with a range of methodologies such as the bicinchoninic protein assay and immunoassays or when surface plasmon resonance (SPR)-based approaches are used. A model system to evaluate these phenomena is proposed. © The Royal Society of Chemistry 2011

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21267470     DOI: 10.1039/c0an00689k

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  6 in total

1.  Automated Immunoassay Performed on a 3D Microfluidic Paper-Based Device for Malaria Detection by Ambient Mass Spectrometry.

Authors:  Sierra Jackson; Suji Lee; Abraham K Badu-Tawiah
Journal:  Anal Chem       Date:  2022-03-16       Impact factor: 8.008

2.  One-step antibody immobilization-based rapid and highly-sensitive sandwich ELISA procedure for potential in vitro diagnostics.

Authors:  Sandeep Kumar Vashist; E Marion Schneider; Edmond Lam; Sabahudin Hrapovic; John H T Luong
Journal:  Sci Rep       Date:  2014-03-18       Impact factor: 4.379

3.  Comparison of 1-Ethyl-3-(3-Dimethylaminopropyl) Carbodiimide Based Strategies to Crosslink Antibodies on Amine-Functionalized Platforms for Immunodiagnostic Applications.

Authors:  Sandeep Kumar Vashist
Journal:  Diagnostics (Basel)       Date:  2012-08-27

Review 4.  Protein Microarrays with Novel Microfluidic Methods: Current Advances.

Authors:  Chandra K Dixit; Gerson R Aguirre
Journal:  Microarrays (Basel)       Date:  2014-07-01

5.  Evaluation of Solid Supports for Slide- and Well-Based Recombinant Antibody Microarrays.

Authors:  Anna S Gerdtsson; Linda Dexlin-Mellby; Payam Delfani; Erica Berglund; Carl A K Borrebaeck; Christer Wingren
Journal:  Microarrays (Basel)       Date:  2016-06-08

Review 6.  Disease-Related Detection with Electrochemical Biosensors: A Review.

Authors:  Ying Huang; Jin Xu; Junjie Liu; Xiangyang Wang; Bin Chen
Journal:  Sensors (Basel)       Date:  2017-10-17       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.