PURPOSE: The study aimed to analyze the validity and reliability of commercially available nondifferential Global Positioning System (NdGPS) devices for measures of total distance during linear, multidirectional and soccer-specific motion at 1-Hz and 5-Hz sampling frequencies. METHODS: Linear (32 trials), multidirectional (192 trials) and soccer-specific courses (40 trials) were created to test the validity (mean ± 90% confidence intervals), reliability (mean ± 90% confidence intervals) and bias (mean ± 90% confidence intervals) of the NdGPS devices against measured distance. Standard error of the estimate established validity, reliability was determined using typical error and percentage bias was established. RESULTS: The 1-Hz and 5-Hz data ranged from 1.3% ± 0.76 to 3.1% ± 1.37 for validity and 2.03% ± 1.31 to 5.31% ± 1.2 for reliability for measures of linear and soccer-specific motion. For multidirectional activity, data ranged from 1.8% ± 0.8 to 6.88% ± 2.99 for validity and from 3.08% ± 1.34 to 7.71% ± 1.65 for reliability. The 1-Hz underestimated some complex courses by up to 11%. CONCLUSIONS: 1-Hz and 5-Hz NdGPS could be used to quantify distance in soccer and similar field-based team sports. Both 1-Hz and 5-Hz have a threshold beyond which reliability is compromised. 1-Hz also underestimates distance and is less valid in more complex courses.
PURPOSE: The study aimed to analyze the validity and reliability of commercially available nondifferential Global Positioning System (NdGPS) devices for measures of total distance during linear, multidirectional and soccer-specific motion at 1-Hz and 5-Hz sampling frequencies. METHODS: Linear (32 trials), multidirectional (192 trials) and soccer-specific courses (40 trials) were created to test the validity (mean ± 90% confidence intervals), reliability (mean ± 90% confidence intervals) and bias (mean ± 90% confidence intervals) of the NdGPS devices against measured distance. Standard error of the estimate established validity, reliability was determined using typical error and percentage bias was established. RESULTS: The 1-Hz and 5-Hz data ranged from 1.3% ± 0.76 to 3.1% ± 1.37 for validity and 2.03% ± 1.31 to 5.31% ± 1.2 for reliability for measures of linear and soccer-specific motion. For multidirectional activity, data ranged from 1.8% ± 0.8 to 6.88% ± 2.99 for validity and from 3.08% ± 1.34 to 7.71% ± 1.65 for reliability. The 1-Hz underestimated some complex courses by up to 11%. CONCLUSIONS: 1-Hz and 5-Hz NdGPS could be used to quantify distance in soccer and similar field-based team sports. Both 1-Hz and 5-Hz have a threshold beyond which reliability is compromised. 1-Hz also underestimates distance and is less valid in more complex courses.
Authors: Julen Castellano; David Casamichana; Julio Calleja-González; Jaime San Román; Sergej M Ostojic Journal: J Sports Sci Med Date: 2011-03-01 Impact factor: 2.988
Authors: Zachary L Crang; Grant Duthie; Michael H Cole; Jonathon Weakley; Adam Hewitt; Rich D Johnston Journal: Sports Med Date: 2020-12-24 Impact factor: 11.136
Authors: Adam Loveday; Lauren B Sherar; James P Sanders; Paul W Sanderson; Dale W Esliger Journal: J Med Internet Res Date: 2015-08-05 Impact factor: 5.428