Literature DB >> 12451579

Multislice breath-hold spiral magnetic resonance coronary angiography in patients with coronary artery disease: effect of intravascular contrast medium.

Patrick R Knuesel1, Daniel Nanz, Ursula Wolfensberger, Manojkumar Saranathan, Anja Lehning, Thomas F Luescher, Borut Marincek, Gustav K von Schulthess, Juerg Schwitter.   

Abstract

PURPOSE: First, to apply a breath-hold multislice 2D spiral magnetic resonance (MR) approach in patients acquiring within 16 heartbeats (acquisition window, 116 msec) a 10-mm-thick stack of four slices (resolution, 1.3 x 1.3 mm(2)); and second, to evaluate the effect of an intravascular Fe-based contrast medium (CM) on a signal-to-noise ratio (SNR) and a contrast-to-noise ratio (CNR).
MATERIALS AND METHODS: In each patient one or two coronary arteries were imaged prior to and following cumulative doses of 0.25, 0.5, and 0.75 mg of Fe/kg of body weight (bw) of an intravascular CM (CLARISCAN trade mark, Nycomed-Amersham, Princeton, NJ, USA) containing ultrasmall superparamagnetic iron oxide (USPIO) particles.
RESULTS: On precontrast maximum intensity projection (MIP) images generated from the stack of slices, 10 and 11 stenoses of 12 stenoses confirmed by coronary angiography were detected by readers 1 and 2, respectively. SNR and CNR in the coronary arteries peaked at 0.50 mg of Fe/kg of bw, yielding a slight increase of 15.5% and 18.4%, respectively (P < 0.05 vs. precontrast), which did not improve detection of coronary artery stenoses.
CONCLUSION: The presented multislice spiral approach allows display of coronary anatomy in MIP formats for convenient display of coronary stenoses. The pulse sequence did not benefit from an intravascular USPIO-based CM, since little improvement in SNR and CNR was achieved. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12451579     DOI: 10.1002/jmri.10202

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Accelerated contrast-enhanced whole-heart coronary MRI using low-dimensional-structure self-learning and thresholding.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Hussein Rayatzadeh; Kraig V Kissinger; Beth Goddu; Lois A Goepfert; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

2.  Utility of respiratory-navigator-rejected k-space lines for improved signal-to-noise ratio in three-dimensional cardiac MR.

Authors:  Mehmet Akçakaya; Jaime L Shaw; Thomas H Hauser; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

3.  Contrast-enhanced whole-heart coronary MRI with bolus infusion of gadobenate dimeglumine at 1.5 T.

Authors:  Peng Hu; Jonathan Chan; Long H Ngo; Jouke Smink; Beth Goddu; Kraig V Kissinger; Lois Goepfert; Thomas H Hauser; Neil M Rofsky; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

4.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.