Literature DB >> 21263332

First multimodal embolization particles visible on x-ray/computed tomography and magnetic resonance imaging.

Soenke H Bartling1, Johannes Budjan, Hagit Aviv, Stefan Haneder, Bettina Kraenzlin, Henrik Michaely, Shlomo Margel, Steffen Diehl, Wolfhard Semmler, Norbert Gretz, Stefan O Schönberg, Maliha Sadick.   

Abstract

OBJECTIVES: Embolization therapy is gaining importance in the treatment of malignant lesions, and even more in benign lesions. Current embolization materials are not visible in imaging modalities. However, it is assumed that directly visible embolization material may provide several advantages over current embolization agents, ranging from particle shunt and reflux prevention to improved therapy control and follow-up assessment. X-ray- as well as magnetic resonance imaging (MRI)-visible embolization materials have been demonstrated in experiments. In this study, we present an embolization material with the property of being visible in more than one imaging modality, namely MRI and x-ray/computed tomography (CT). Characterization and testing of the substance in animal models was performed.
MATERIALS AND METHODS: To reduce the chance of adverse reactions and to facilitate clinical approval, materials have been applied that are similar to those that are approved and being used on a routine basis in diagnostic imaging. Therefore, x-ray-visible Iodine was combined with MRI-visible Iron (Fe3O4) in a macroparticle (diameter, 40-200 μm). Its core, consisting of a copolymerized monomer MAOETIB (2-methacryloyloxyethyl [2,3,5-triiodobenzoate]), was coated with ultra-small paramagnetic iron oxide nanoparticles (150 nm). After in vitro testing, including signal to noise measurements in CT and MRI (n = 5), its ability to embolize tissue was tested in an established tumor embolization model in rabbits (n = 6). Digital subtraction angiography (DSA) (Integris, Philips), CT (Definition, Siemens Healthcare Section, Forchheim, Germany), and MRI (3 Tesla Magnetom Tim Trio MRI, Siemens Healthcare Section, Forchheim, Germany) were performed before, during, and after embolization. Imaging signal changes that could be attributed to embolization particles were assessed by visual inspection and rated on an ordinal scale by 3 radiologists, from 1 to 3. Histologic analysis of organs was performed.
RESULTS: Particles provided a sufficient image contrast on DSA, CT (signal to noise [SNR], 13 ± 2.5), and MRI (SNR, 35 ± 1) in in vitro scans. Successful embolization of renal tissue was confirmed by catheter angiography, revealing at least partial perfusion stop in all kidneys. Signal changes that were attributed to particles residing within the kidney were found in all cases in all the 3 imaging modalities. Localization distribution of particles corresponded well in all imaging modalities. Dynamic imaging during embolization provided real-time monitoring of the inflow of embolization particles within DSA, CT, and MRI. Histologic visualization of the residing particles as well as associated thrombosis in renal arteries could be performed. Visual assessment of the likelihood of embolization particle presence received full rating scores (153/153) after embolization.
CONCLUSIONS: Multimodal-visible embolization particles have been developed, characterized, and tested in vivo in an animal model. Their implementation in clinical radiology may provide optimization of embolization procedures with regard to prevention of particle misplacement and direct intraprocedural visualization, at the same time improving follow-up examinations by utilizing the complementary characteristics of CT and MRI. Radiation dose savings can also be considered. All these advantages could contribute to future refinements and improvements in embolization therapy. Additionally, new approaches in embolization research may open up.

Entities:  

Mesh:

Year:  2011        PMID: 21263332     DOI: 10.1097/RLI.0b013e318205af53

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  11 in total

1.  Value of MR contrast media in image-guided body interventions.

Authors:  Maythem Saeed; Mark Wilson
Journal:  World J Radiol       Date:  2012-01-28

Review 2.  Locoregional drug delivery using image-guided intra-arterial drug eluting bead therapy.

Authors:  Andrew L Lewis; Matthew R Dreher
Journal:  J Control Release       Date:  2012-01-21       Impact factor: 9.776

Review 3.  Advances in Biomaterials and Technologies for Vascular Embolization.

Authors:  Jingjie Hu; Hassan Albadawi; Brian W Chong; Amy R Deipolyi; Rahul A Sheth; Ali Khademhosseini; Rahmi Oklu
Journal:  Adv Mater       Date:  2019-06-06       Impact factor: 30.849

4.  Synthesis and characterization of image-able polyvinyl alcohol microspheres for image-guided chemoembolization.

Authors:  Ayele H Negussie; Matthew R Dreher; Carmen Gacchina Johnson; Yiqing Tang; Andrew L Lewis; Gert Storm; Karun V Sharma; Bradford J Wood
Journal:  J Mater Sci Mater Med       Date:  2015-06-24       Impact factor: 3.896

5.  Radiopaque drug-eluting beads for transcatheter embolotherapy: experimental study of drug penetration and coverage in swine.

Authors:  Matthew R Dreher; Karun V Sharma; David L Woods; Goutham Reddy; Yiqing Tang; William F Pritchard; Oscar A Chiesa; John W Karanian; Juan A Esparza; Danielle Donahue; Elliot B Levy; Sean L Willis; Andrew L Lewis; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2011-12-16       Impact factor: 3.464

6.  Superparamagnetic iron oxide nanoparticles function as a long-term, multi-modal imaging label for non-invasive tracking of implanted progenitor cells.

Authors:  Christina A Pacak; Peter E Hammer; Allison A MacKay; Rory P Dowd; Kai-Roy Wang; Akihiro Masuzawa; Bjoern Sill; James D McCully; Douglas B Cowan
Journal:  PLoS One       Date:  2014-09-24       Impact factor: 3.240

7.  A Novel Inherently Radiopaque Bead for Transarterial Embolization to Treat Liver Cancer - A Pre-clinical Study.

Authors:  Rafael Duran; Karun Sharma; Matthew R Dreher; Koorosh Ashrafi; Sahar Mirpour; MingDe Lin; Ruediger E Schernthaner; Todd R Schlachter; Vania Tacher; Andrew L Lewis; Sean Willis; Mark den Hartog; Alessandro Radaelli; Ayele H Negussie; Bradford J Wood; Jean-François H Geschwind
Journal:  Theranostics       Date:  2016-01-01       Impact factor: 11.556

8.  1,3-Bis(2-chloroethyl)-1-nitrosourea-loaded bovine serum albumin nanoparticles with dual magnetic resonance-fluorescence imaging for tracking of chemotherapeutic agents.

Authors:  Kuo-Chen Wei; Feng-Wei Lin; Chiung-Yin Huang; Chen-Chi M Ma; Ju-Yu Chen; Li-Ying Feng; Hung-Wei Yang
Journal:  Int J Nanomedicine       Date:  2016-08-23

9.  SPPS resins impact the PNA-syntheses' improvement.

Authors:  Rüdiger Pipkorn; Stephan Rawer; Manfred Wiessler; Waldemar Waldeck; Mario Koch; Hans Hermann Schrenk; Klaus Braun
Journal:  Int J Med Sci       Date:  2013-02-13       Impact factor: 3.738

Review 10.  Nanoparticles for imaging: top or flop?

Authors:  Fabian Kiessling; Marianne E Mertens; Jan Grimm; Twan Lammers
Journal:  Radiology       Date:  2014-10       Impact factor: 11.105

View more