Literature DB >> 21258073

Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery.

S H Kim1, S Y Park, J Cui, J H Lee, S H Cho, W S Chae, H C Jin, K H Hwang.   

Abstract

BACKGROUND: Peripheral venous pressure (PVP) is strongly correlated with central venous pressure (CVP) during various surgeries. Laparoscopic surgery in the Trendelenburg position with pneumoperitoneum typically increases CVP. To determine whether PVP convincingly reflects changes in CVP, we evaluated the correlation between PVP and CVP in patients undergoing laparoscopic colorectal surgery.
METHODS: Both CVP and PVP were measured simultaneously at predetermined time intervals during elective laparoscopic colorectal surgery in 42 patients without cardiac disease. The pairs of venous pressure measurements were analysed for correlation, and the Bland-Altman plots of repeated measures were used to evaluate the agreement between CVP and PVP.
RESULTS: A total of 420 data pairs were obtained. The overall mean CVP was 11.3 (sd 4.5) mm Hg, which was significantly lower than the measured PVP of mean 12.1 (4.5) mm Hg (P=0.005). There was a strong positive correlation between overall CVP and PVP (correlation coefficient=0.96, P<0.0001). The mean bias (PVP-CVP) corrected for repeated measurements using random-effects modelling was 0.9 mm Hg [95% confidence interval (CI) 0.54-1.19 mm Hg] with 95% limits of agreement of -1.2 mm Hg (95% CI -1.75 to -0.62 mm Hg) to 2.9 mm Hg (95% CI 2.35-3.48 mm Hg).
CONCLUSIONS: PVP displays a strong correlation and agreement with CVP under the increased intrathoracic pressure of pneumoperitoneum in the Trendelenburg position and may be used as an alternative to CVP in patients without cardiac disease undergoing laparoscopic colorectal surgery.

Entities:  

Mesh:

Year:  2011        PMID: 21258073     DOI: 10.1093/bja/aeq399

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Intraoperative monitoring of stroke volume variation versus central venous pressure in laparoscopic liver surgery: a randomized prospective comparative trial.

Authors:  Francesca Ratti; Federica Cipriani; Raffaella Reineke; Marco Catena; Michele Paganelli; Laura Comotti; Luigi Beretta; Luca Aldrighetti
Journal:  HPB (Oxford)       Date:  2015-11-17       Impact factor: 3.647

2.  Analysis of central venous pressure (CVP) signals using mathematical methods.

Authors:  Parham Atefvahid; Kamran Hassani; Kamal Jafarian; D John Doyle; Hessam Ahmadi
Journal:  J Clin Monit Comput       Date:  2016-05-03       Impact factor: 2.502

3.  Comparative utility of centrally versus peripherally transduced venous pressure monitoring in the perioperative period in spine surgery patients.

Authors:  Anna Maria Bombardieri; James Beckman; Pamela Shaw; Federico P Girardi; Yan Ma; Stavros G Memtsoudis
Journal:  J Clin Anesth       Date:  2012-09-20       Impact factor: 9.452

4.  Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery.

Authors:  Yanhong Liu; May C M Pian-Smith; Lisa R Leffert; Rebecca D Minehart; Andrea Torri; Charles Coté; Robert M Kacmarek; Yandong Jiang
Journal:  J Clin Monit Comput       Date:  2014-12-16       Impact factor: 2.502

5.  Assessment of surgical outcomes of off-clamp open partial nephrectomy without renorrhaphy for ≥T1b renal tumours.

Authors:  Masaki Nakamura; Yoshiki Ambe; Taro Teshima; Norihide Shirakawa; Hiroki Inatsu; Ryo Amakawa; Yasushi Inoue; Tadashi Yoshimatsu; Shunsuke Imai; Masashi Kusakabe; Teppei Morikawa; Shuji Kameyama; Yoshiyuki Shiga
Journal:  Int J Clin Oncol       Date:  2021-06-16       Impact factor: 3.402

6.  Peripheral venous pressure to monitor fluid resuscitation in burns-more confusing than helpful?

Authors:  Lavrentieva Athina
Journal:  Indian J Crit Care Med       Date:  2015-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.