Literature DB >> 21254024

Comparison of three separate antiadhesive barriers for intraperitoneal onlay mesh hernia repair in an experimental model.

S Gruber-Blum1, A H Petter-Puchner, J Brand, R H Fortelny, N Walder, W Oehlinger, F Koenig, H Redl.   

Abstract

BACKGROUND: Adhesion formation is a common adverse effect in intraperitoneal onlay mesh (IPOM) surgery. Different methods of adhesion prevention have been developed, including coated meshes and separate antiadhesive barriers (SABs). In this study one type of mesh was tested with different SABs, which were fixed to the sutured mesh using fibrin sealant. The primary aim was to compare adhesion prevention between different SABs. Secondary aims were the assessment of tissue integration and evaluation of SAB fixation with fibrin sealant.
METHODS: Thirty-two rats were randomized to one of three treatment groups (SurgiWrap, Prevadh and Seprafilm) or a control group (no SAB). Animals were operated on with an open IPOM technique (8 per group). One macroporous polypropylene mesh per animal (2 × 2 cm) was fixed with four non-absorbable sutures. An antiadhesive barrier of 2·5 × 2·5 cm was fixed with fibrin sealant. After 30 days, adhesion formation, tissue integration, seroma formation, inflammation and vascularization were evaluated macroscopically and by histology.
RESULTS: Prevadh and Seprafilm groups showed a significant reduction in adhesion formation compared with the control group. Tissue integration of the mesh was reduced in these groups. Fibrin sealant fixed the SAB to the mesh securely in all groups.
CONCLUSION: Prevadh and Seprafilm are potent materials for the reduction of adhesion formation. A potential relationship between effective adhesion prevention and impaired tissue integration of the implant was observed. Fibrin sealant proved an excellent agent for SAB fixation.
Copyright © 2010 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21254024     DOI: 10.1002/bjs.7334

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  13 in total

Review 1.  Current strategies and future perspectives for intraperitoneal adhesion prevention.

Authors:  Christoph Brochhausen; Volker H Schmitt; Constanze N E Planck; Taufiek K Rajab; David Hollemann; Christine Tapprich; Bernhard Krämer; Christian Wallwiener; Helmut Hierlemann; Rolf Zehbe; Heinrich Planck; C James Kirkpatrick
Journal:  J Gastrointest Surg       Date:  2012-06       Impact factor: 3.452

2.  Laparoscopic ventral hernia repair using a novel intraperitoneal lightweight mesh coated with hyaluronic acid: 1-year follow-up from a case-control study using the Hernia-Club registry.

Authors:  J-F Gillion; G Fromont; M Lepère; N Letoux; A Dabrowski; C Zaranis; C Barrat
Journal:  Hernia       Date:  2016-06-09       Impact factor: 4.739

Review 3.  Mesh biocompatibility: effects of cellular inflammation and tissue remodelling.

Authors:  Karsten Junge; Marcel Binnebösel; Klaus T von Trotha; Raphael Rosch; Uwe Klinge; Ulf P Neumann; Petra Lynen Jansen
Journal:  Langenbecks Arch Surg       Date:  2011-04-01       Impact factor: 3.445

4.  Fixation of polyvinylidene fluoride (PVDF) mesh with cyanoacrylate-derived glues in a rat experimental model: histopathologic immunohistochemical and morphometric study.

Authors:  A Poli; F Parisi; F Millanta; L Solfanelli; P García-Pastor; C Magliaro; V Miragliotta; S Burchielli
Journal:  Hernia       Date:  2019-11-26       Impact factor: 4.739

5.  Liquid antiadhesive agents for intraperitoneal hernia repair procedures: Artiss® compared to CoSeal® and Adept® in an IPOM rat model.

Authors:  Simone Gruber-Blum; R H Fortelny; C Keibl; J Brand; M Lechner; H Redl; A H Petter-Puchner
Journal:  Surg Endosc       Date:  2016-10-31       Impact factor: 4.584

6.  The impact of hydrophobic hernia mesh coating by omega fatty acid on atraumatic fibrin sealant fixation.

Authors:  S Gruber-Blum; J Brand; C Keibl; H Redl; R H Fortelny; C May; A H Petter-Puchner
Journal:  Hernia       Date:  2014-09-07       Impact factor: 4.739

7.  Polypropelene mesh eroding transverse colon following laparoscopic ventral hernia repair.

Authors:  Manash Ranjan Sahoo; Suryakanta Bisoi; Santosh Mathapati
Journal:  J Minim Access Surg       Date:  2013-01       Impact factor: 1.407

8.  Tolerance and long-term MRI imaging of gadolinium-modified meshes used in soft organ repair.

Authors:  Vincent Letouzey; Stéphanie Huberlant; Arnaud Cornille; Sébastien Blanquer; Olivier Guillaume; Laurent Lemaire; Xavier Garric; Renaud de Tayrac
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

9.  Barrier agents for adhesion prevention after gynaecological surgery.

Authors:  Gaity Ahmad; Kyungmin Kim; Matthew Thompson; Priya Agarwal; Helena O'Flynn; Akshay Hindocha; Andrew Watson
Journal:  Cochrane Database Syst Rev       Date:  2020-03-22

10.  A randomized controlled experimental study comparing chitosan coated polypropylene mesh and Proceed™ mesh for abdominal wall defect closure.

Authors:  S T Jayanth; Anna Pulimood; Deepak Abraham; A Rajaram; M J Paul; Aravindan Nair
Journal:  Ann Med Surg (Lond)       Date:  2015-10-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.