Literature DB >> 21247057

The evaluation of selected attachment systems for implant-retained overdenture based on retention characteristics analysis.

Grzegorz Chladek1, Marcin Wrzuś-Wieliński.   

Abstract

The results of mechanical characteristics of attachments used for retaining and stabilizing overdenture have been analysed. Two commercially used attachments (a ball attachment and a bar attachment) and elastic frictional attachments designed by the research team with Professor Chladek as the leader have been investigated. The diagrams of force-displacement characteristics have been registered. Retention forces (F(R)) have been determined and total work (W(T)) disconnecting the attachments has been calculated on the basis of these diagrams. The analysis of total work corresponding to different types of attachments made it possible to distinguish some characteristic areas which illustrate specific features of particular designs. It has been revealed that determining the retention force allows us to compare only the attachments which work on similar bases. In order to conduct a purely objective comparison of the efficiency of different designs, it is necessary to analyze complete force-displacement characteristics as well as to determine on this basis the subsequent phases of separating the parts of attachments and to find the value of the work which in fact determines their quality. The comparison of selected commercially used designs and the presented elastic frictional attachments (taking into account the criterion of work) gives clear evidence that the introduced design of attachment enables us to create very good conditions of retaining overdenture.

Mesh:

Substances:

Year:  2010        PMID: 21247057

Source DB:  PubMed          Journal:  Acta Bioeng Biomech        ISSN: 1509-409X            Impact factor:   1.073


  5 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Antifungal activity of denture soft lining material modified by silver nanoparticles-a pilot study.

Authors:  Grzegorz Chladek; Anna Mertas; Izabela Barszczewska-Rybarek; Teresa Nalewajek; Jarosław Zmudzki; Wojciech Król; Jan Lukaszczyk
Journal:  Int J Mol Sci       Date:  2011-07-22       Impact factor: 5.923

Review 3.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

Review 4.  Long-Term Soft Denture Lining Materials.

Authors:  Grzegorz Chladek; Jarosław Żmudzki; Jacek Kasperski
Journal:  Materials (Basel)       Date:  2014-08-12       Impact factor: 3.623

5.  Effect of Silver-Emitting Filler on Antimicrobial and Mechanical Properties of Soft Denture Lining Material.

Authors:  Ewa Jabłońska-Stencel; Wojciech Pakieła; Anna Mertas; Elżbieta Bobela; Jacek Kasperski; Grzegorz Chladek
Journal:  Materials (Basel)       Date:  2018-02-22       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.